[PDF][PDF] New methods of examining gamma camera collimators

W Chang, S Li, JJ Williams, PM Bruch… - Journal of nuclear …, 1988 - Soc Nuclear Med
MATERIALS AND METhODS Collimator Uniformity A specialrectilinearscanner was
employedto measurethe uniformity of collimators. This scanner is similar to a com mercially …

[CITATION][C] A diverging collimator for gamma-ray imaging cameras

G Muehllehner - Journal of Nuclear Medicine, 1969 - Soc Nuclear Med
The diverging collimator gives a field of view that is large enough for practically all clinical
applications. It can be used with existing 10-in.-diameter cameras, thus largely eliminating …

[PDF][PDF] Physical specification of a gamma camera

BR Westerman, HI Glass - Journal of Nuclear Medicine, 1968 - Soc Nuclear Med
Because the aim of this paper is to discuss the performance of the camera in terms of
parameters that are measured easily, the following definition of resolution will be used …

Elimination of Collimator Artifacts in Scintillation-Camera Imaqes

RC Bramlet - Radiology, 1970 - pubs.rsna.org
An experimental arrangement which permitted the parallel multihole collimator of a gamma
camera to be set in rotary motion during image formation was fabricated. Various test …

[HTML][HTML] The evaluation of straight-bore, tapered and focusing collimators as a function of gamma-ray energy

WJ MacIntyre, JH Christie, I Tatsuno - Medical Radioisotope Scanning …, 1964 - inis.iaea.org
[en] In the choice of one collimator or type of collimator over another for scanning purposes,
either isoresponse curves or the geometric response to a point source has been previously …

The experimental evaluation of a prototype rotating slat collimator for planar gamma camera imaging

MA Lodge, DM Binnie, MA Flower… - Physics in Medicine & …, 1995 - iopscience.iop.org
A collimator consisting of a series of parallel slats has been constructed and used in
conjunction with a conventional gamma camera to collect one-dimensional projections of …

Evaluation of Focused Collimator Performance III. Three- and Five-Inch-Diameter Collimators For 131I and 99mTc

GJ Hine, SP Tsialas - … Radioisotope Scintigraphy. VI Proceedings of a …, 1969 - inis.iaea.org
[en] Focused collimators for radioisotope scanning must be chosen according to their spatial
resolution as a function of source-to-collimator distance, their plane-source sensitivity, and …

The fan-beam gamma camera

WI Keyes - Physics in Medicine & Biology, 1975 - iopscience.iop.org
A device employing a slit collimator which limits the angle of acceptance of the gamma-rays
in only one direction is introduced. Each point in the activity distribution is thus emitting into …

[PDF][PDF] Analysis and correction of spatial distortions produced by the gamma camera

SS Spector, VA Brookeman, CD Kylstra… - Journal of Nuclear …, 1972 - Soc Nuclear Med
Two types of distortions are produced by the gamma camera. One is nonuniform sensitivity
re sponse over the detecting area. The second is spatial distortion; that is, the displacement …

[PDF][PDF] Collimator performance for scintillation camera systems

VA Brookeman, TJ Bauer - Journal of Nuclear Medicine, 1973 - Soc Nuclear Med
MATERIALS AND METHODS Systems description. The imaging systems studied were a
Pho/Gamma III scintillation camera, initially with conventional S-11 phototubes and later with …