[CITATION][C] Distribution of 14C-Diphenylhydantoin in Pancreas Islet Cell and Other Tissues of Toadfish

UY Ryo, MJ Shaw, WH Beierwaltes… - Journal of Nuclear …, 1974 - Soc Nuclear Med
Tissue distribution of 14C-diphenylhydantoin (14C-DPH) in the toadfish, with particular
reference to the pancreatic islet cells, was studied in 24 toadfish at intervals of 10 min to 72 …

[PDF][PDF] Tissue Distribution of 14C-, 125I-, and 131I-Diphenylhydantoin in the Toadfish, Rat, and Human with Insulinomas

S Balachandran, WH Beierwaltes, RD Ice… - Journal of Nuclear …, 1975 - Soc Nuclear Med
Carbon-14-diphenylhydantoin(DPH) concen trated maximally in pancreatic islet cells of the
toad/ish 10 mm after its intravenous adminis tration. The islet cell-to-acinar-tissue ratio at this …

Accumulation and metabolism of [125I] HIPDM in the rat pancreas

H Saji, Y Kuge, D Tsutsumi, K Yamamoto… - Annals of Nuclear …, 1991 - Springer
Our previous studies have shown a high accumulation of [125 I] N, N, N′-trimethyl-N′-(2-
hydroxy-3-methyl-5-iodobenzyl)-l, 3-propanediamine (HIPDM) in the human pancreas. In …

In vivo distribution of carbon-11 phenytoin and its major metabolite, and their use in scintigraphic imaging.

SA Stavchansky, RS Tilbury, JM McDonald… - Journal of Nuclear …, 1978 - europepmc.org
Curie quantities (0.3--1.5 Ci) of H11CN were used in the synthesis of C-11-tagged phenytoin
(C-11. DPH) and 5-(p-hydroxyphenyl)-5-phenylhydantoin (C-11. HPPH), using a modified …

[PDF][PDF] Hepatobiliary handling of iodine-125-Tyr3-octreotide and indium-111-DTPA-D-Phe1-octreotide by isolated perfused rat liver

M de Jong, WH Bakker, WAP Breeman… - Journal of Nuclear …, 1993 - Soc Nuclear Med
RESULTS IodIne-I25. 1@ ctreotIde Figure 2 shows typical time courses of total radioactiv ity,
peptide-bound radioactivity and liberated 1@ Iin the medium and bile after …

The synthesis, radioiodination and preliminary biological study of the new carboxylic derivatives of dithizone

P Garnuszek, I Liciñska, P Fiedor… - Applied radiation and …, 1998 - Elsevier
Synthesis, characteristics and radioiodination of the new carboxylic derivatives of dithizone
are described in this paper. We have applied the carboxy dithizones for preparation of …

Potential organ or tumor imaging agents XV: Radioiodinated phenytoin derivatives

RE Counsell, VV Ranade, W Kline, BH Hong… - Journal of …, 1976 - Elsevier
Three radioiodinated phenytoin analogs were synthesized, and tissue distribution studies
were conducted in rats. Except for a greater retention of radioactivity following administration …

Turnover of 14C-labelled L-histidine and its incorporation into carnosine and anserine in rainbow trout.

PW Hochachka - 日本水産学会誌, 1987 - jlc.jst.go.jp
Metabolic half-life of L-[U-14 C] histidine was detemined on the blood and white muscle of
rainbow trout Salmo gairdneri, Incorporation of the label into histidine related dipeptides …

Radioimmunoassay of phenytoin

G Samuel, N Sivaprasad, R Mani - Journal of radioanalytical and …, 1991 - akjournals.com
We describe a radioimmunoassay procedure for the measurement of phenytoin (5, 5-
diphenylhydantoin) in serum samples. Antiserum to phenytoin has been produced against …

[PDF][PDF] Effect of dose and specific activity on tissue distribution of indium-111-pentetreotide in rats

WAP Breeman, DJ Kwekkeboom… - Journal of Nuclear …, 1995 - Soc Nuclear Med
RESULTS Expedment A Significant specific tissue binding of †œIn-pentetreotide was
observed in the octreotide receptor-positive anterior pituitary gland, adrenals, and pancreas …