[PDF][PDF] A potential new brain-scanning agent: 4-77Br-2, 5-dimethoxyphenylisopropylamine (4-Br-DPIA)

T Sargent, DA Kalbhen, AT Shulgin… - Journal of Nuclear …, 1975 - Soc Nuclear Med
FIG. 1. SubjectB. Scintiscansof iv@ †Br. DPlAwith Mark II whole-body scanner, reproduced
from data collected on-line and stored in HP 5047A computer.(A) This frame is body outline …

Preparation of 18F-labeled 6-and 2-fluoro-9-benzylpurine as a potential brain-scanning agent

T Irie, K Fukushi, O Inoue, T Yamasaki, T Ido… - … International Journal of …, 1982 - Elsevier
Abstract The preparations of [18 F]-6-fluoro-9-benzylpurine (I) and [18 F]-2-fluoro-9-
benzylpurine (II) are described.(I) was prepared by two methods:(i) halogen exchange of 6 …

Evaluation of ytterbium-169 diethylenetriaminepentaacetic acid as a brain-scanning agent

DL Gilday, RC Reba, F Hosain, R Longo… - Radiology, 1969 - pubs.rsna.org
THE FIRST widely used short-lived radiopharmaceutical for brain scanning was technetium-
99m pertechnetate introduced by Harper et al. in 1964 (3). Recently, a second short-lived …

[PDF][PDF] Studies on the Tissue Distribution of 125I-Iodopropamide in the Dog

CM Boyd, GN Holcomb, RE Counsell… - Journal of Nuclear …, 1971 - Soc Nuclear Med
METHOD Four normal adult beagle dogs were slowly in jected intravenously with 100 pCi of
125I-Iodopropamide, which contained approximately 4 mg of the chemical dissolved in 90 …

[PDF][PDF] Organic radiopharmaceuticals labeled with isotopes of short half-life I: 11C-1-dopamine hydrochloride

DR Christman, RM Hoyte, AP Wolf - Journal of Nuclear Medicine, 1970 - Soc Nuclear Med
FIG. 1. Organicradiopharmaceutical producflon. ferred to a lead pig using tongs. When ready
for use, the foil package is removed from the pig, cut in half and the dark grey powder is …

[CITATION][C] A preliminary evaluation of F18-labeled tetrafluoroborate as a scanning agent for intracranial tumors

W Entzian, S Aronow, AH Soloway… - Journal of Nuclear …, 1964 - Soc Nuclear Med
Summary F18, 112 minute half-life positron-emitter was studied as a possible agent for brain
tumor localization. Tissue studies in mice bearing subcutaneously transplanted tumors …

[PDF][PDF] A simplified method for the preparation of indium-DTPA brain scanning agent

T Hill, MJ Welch, M Adatepe… - Journal of Nuclear …, 1970 - Soc Nuclear Med
A SIMPLIFIED METHOD FOR THE PREPARATION OF INDIUM-DTPA BRAIN SCANNING
AGENT Page 1 BRAIN Recently various articles have been published outlining the method of …

[CITATION][C] 99mTc-DTPA in cerebral scanning

IS Jenkinson, P Wright, P Sorby - … Journal of Nuclear Medicine and Biology, 1975 - Elsevier
RADIOISOTOPIC detection of intracerebral spaceoccupying lesions depends on the
presence of increased density of a radiopharmaceutical in the locality of the lesion. This can …

Iodine-122-labeled amphetamine derivative with potential for PET brain blood-flow studies.

CA Mathis, T Sargent 3rd, AT Shulgin - Journal of Nuclear Medicine …, 1985 - europepmc.org
The positron emitter 122I (t1/2 3.6 min) was collected from a xenon-122/iodine-122
(122Xe/122I) generator and incorporated into an amphetamine analog, 2, 4-dimethoxy-N, N …

Diatrizoate Contrast Agents: Studies on the Metabolism of Diacetamido-, 3-Amino-5-acetamido-, and 3, 5-Diamino-2, 4, 6-triiodobenzoates

R Weiss, B Hsu, L Wheeler, A Norman… - Investigative …, 1981 - journals.lww.com
We have examined the metabolic behavior of several triiodobenzoic acid derivatives
because of the observed mutagenicity and cytotoxicity of 3-amino-5-acetamido-2, 4, 6 …