[PDF][PDF] Use of 99mTc-DTPA for measuring gastric emptying time

TK Chaudhuri - Journal of Nuclear Medicine, 1974 - Soc Nuclear Med
USE OF 99mTc-DTPA FOR MEASURING GASTRIC EMPTYING TIME Page 1 A rapid
andeasyisotopicmethodfor measur ing gastric emptying time (GET) is described. It involves the …

[PDF][PDF] Biologic gastric emptying time in diabetic patients, using Tc-99m-labeled resin-oatmeal with and without metoclopramide

PA Domstad, EE Kim, JJ Coupal, R Beihn… - Journal of Nuclear …, 1980 - Soc Nuclear Med
MATERIALS AND METHODS There were 24 diabetic patients for whom complete data were
available. The ages ranged from 22 to 64 yr (mean 39); there were 13 women and 11 men …

Comprehensive radionuclide esophagogastrointestinal transit study: methodology, reference values, and initial clinical experience

AJ Antoniou, S Raja, R El-Khouli, E Mena… - Journal of Nuclear …, 2015 - Soc Nuclear Med
A radionuclide methodology and reference values have been developed for a single
gastrointestinal transit study including esophageal transit, liquid and solid gastric emptying …

Effects of meal size and correction technique on gastric emptying time: studies with two tracers and opposed detectors.

PE Christian, JG Moore, JA Sorenson… - Journal of nuclear …, 1980 - europepmc.org
Geometric-mean correction of gastric radioactivity can be used to correct for the distribution,
depth, and attenuation of the radionuclide. Anterior image counts were compared with the …

[PDF][PDF] Use of technetium-99m (V) thiocyanate to measure gastric emptying of fat

KM Cunningham, RJ Baker, M Horowitz… - Journal of Nuclear …, 1991 - Soc Nuclear Med
Olive oil was labeled with 99mTc (VXSCN) by direct extraction from acidic thiocyanate
solution according to the following method (13). Technetium-99m-pertechnetate (100— …

99mTc-Human Albumin Microspheres (HAM) for Measuring the Rate of Gastric Emptying

M Calderon, RE Sonnemaker, T Hersh, JA Burdine - Radiology, 1971 - pubs.rsna.org
The radiopharmaceutical HAM (99mTc-human albumin microspheres) was used to measure
gastric emptying time in a series of 29 patients (normal, 9; duodenal ulcer, 7; gastric ulcer, 7; …

Comparison of methods for analyzing gastric isotope emptying

MC Dugas, RR Schade, D Lhotsky… - American Journal of …, 1982 - journals.physiology.org
The gastric emptying of 99mTc-sulfur colloid, ingested in a nutrient liquid test meal, was
followed by gamma camera for normals, diabetics, and diabetics receiving intravenous …

[PDF][PDF] Evaluation of an inexpensive screening scintigraphic test of gastric emptying

GM Thomforde, M Camilleri, SF Phillips… - Journal of Nuclear …, 1995 - Soc Nuclear Med
Our goal was to study the accuracy of a limited assessment relative to the traditional and
obtain a more detailed approach to measure gastric emptying. Methods: We prospectively …

Experience with a simplified, standardized 4-hour gastric-emptying protocol

HA Ziessman, DV Bonta, S Goetze… - Journal of Nuclear …, 2007 - Soc Nuclear Med
Gastric-emptying studies have no accepted standard methodology or reference values. A
simplified standardized protocol with a large reference database has been proposed, with …

An evaluation of 113mindium DTPA chelate in the measurement of gastric emptying by scintiscanning

RC Heading, P Tothill, AJ Laidlaw, DJC Shearman - Gut, 1971 - gut.bmj.com
The sequential scintiscanning technique was used to determine gastric emptying rates in
adult human subjects after ingestion of a meal of cornflakes and milk to which a gamma …