[PDF][PDF] A new algorithm for the quantitation of myocardial perfusion SPECT. II: validation and diagnostic yield

T Sharir, G Germano, PB Waechter… - Journal of Nuclear …, 2000 - Soc Nuclear Med
This study validates a new quantitative perfusion SPECT algo rithmforthe assessmentof
myocardialperfusion. The algorithm is not based on slices and providesfully 3 …

[PDF][PDF] A new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principles and reproducibility

G Germano, PB Kavanagh, P Waechter… - Journal of nuclear …, 2000 - Soc Nuclear Med
The new algorithm was tested on the tomographic images of420 patientsstudiedwith a rest@
Â1Tl (11— 167MBq, 35 s/projection) — stress@ †œTc-sestamibi (925— 1480MBq, 25 …

Automated quantification of myocardial perfusion SPECT using simplified normal limits

PJ Slomka, H Nishina, DS Berman… - Journal of nuclear …, 2005 - Springer
Background. To simplify development of normal limits for myocardial perfusion SPECT
(MPS), we implemented a quantification scheme in which normal limits are derived without …

[PDF][PDF] On the accuracy and reproducibility of quantitative gated myocardial perfusion SPECT

G Germano, DS Berman - Journal of Nuclear Medicine, 1999 - Soc Nuclear Med
he use of electrocardiographic gat ing in conjunction with myocardial perfusion SPECT
imaging has in creased so much over the past 5 y that gated myocardial perfusion SPECT …

Quantitative myocardial-perfusion SPECT: comparison of three state-of-the-art software packages

A Wolak, PJ Slomka, MB Fish, S Lorenzo… - Journal of nuclear …, 2008 - Springer
Background We almed to compare the automation and diagnostic performance in the
detection of coronary artery disease (CAD) of the 4DMSPECT (4DM), Emory Cardiac …

Automatic and visual reproducibility of perfusion and function measures for myocardial perfusion SPECT

Y Xu, S Hayes, I Ali, TD Ruddy, RG Wells… - Journal of nuclear …, 2010 - Elsevier
Background We define the repeatability coefficients (RC) of key quantitative and visual
perfusion and function parameters that can be derived by the QGS/QPS automated software …

Quantitative myocardial perfusion SPECT

BMW Tsui, EC Frey, KJ LaCroix, DS Lalush… - Journal of Nuclear …, 1998 - Elsevier
In recent years, there has been much interest in the clinical application of attenuation
compensation to myocardial perfusion single photon emission computed tomography …

Quantitative analysis of SPECT myocardial perfusion

KF Van Train, EV Garcia, CD Cooke… - … SPECT imaging. 2nd …, 2001 - books.google.com
Quantitative analysis of single photon emission computed tomography (SPECT) myocardial
perfusion imaging has undergone moderate changes since the first edition of this book was …

Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT

DP Lum, MN Coel - Nuclear medicine communications, 2003 - journals.lww.com
The aim of this study was to compare the performance of three different software packages
for the calculation of ejection fraction (EF) and end diastolic volume (EDV) from gated …

Advances in quantitative perfusion SPECT imaging

EP Ficaro, JR Corbett - Journal of nuclear Cardiology, 2004 - Springer
Quantitative software for myocardial perfusion single photon emission computed
tomography (SPECT) has advanced significantly over the last 25 years. The strength and …