Image characteristics of brain perfusion SPECT/CT using a new multi-focal collimator: Comparison with conventional SPECT with LEHR collimator

T Shibutani, M Onoguchi, T Nishiyama, AH Vija… - 2022 - Soc Nuclear Med
4116 Introduction: A new multi-focal SMARTZoom class collimator with a suitable high
resolution and extended magnification volume (SZHRX) is applied to cardiology and …

Multicenter trial study for usefulness of physical parameters toward the standardization of brain SPECT image: relation to visual analysis

A Sugiura, M Onoguchi, T Shibutani, A Nagaki… - 2023 - Soc Nuclear Med
T5 Introduction: While brain perfusion single-photon emission computed tomography
(SPECT) imaging has been widely used to measure regional cerebral perfusion and is …

[HTML][HTML] High-quality brain perfusion SPECT images may be achieved with a high-speed recording using 360° CZT camera

M Bordonne, MB Chawki, PY Marie, T Zaragori, V Roch… - EJNMMI physics, 2020 - Springer
Objective The aim of this study was to compare brain perfusion SPECT obtained from a 360°
CZT and a conventional Anger camera. Methods The 360° CZT camera utilizing a brain …

Effect of the skull on brain perfusion SPECT imaging

S Matsuoka, H Shinohara, T Yamamoto… - … zasshi. Nippon Acta …, 1998 - europepmc.org
Because attenuation gradually decreases reconstructed counts from the periphery to the
center portion of the object, the deep region far from the detector is not clearly observed if …

Simulating technetium-99m cerebral perfusion studies with a three-dimensional Hoffman brain phantom: collimator and filter selection in SPECT neuroimaging

HJ Kim, JS Karp, PD Mozley, SO Yang… - Annals of nuclear …, 1996 - Springer
The choice of a collimator and the selection of a filter can affect the quality of clinical SPECT
images of the brain. The compromises that 4 different collimators make between spatial …

Performance of a novel collimator for high‐sensitivity brain SPECT

GE Fakhri, J Ouyang, RE Zimmerman… - Medical …, 2006 - Wiley Online Library
We assessed improvements in performance in detection and estimation tasks due to a novel
brain single photon computed tomography collimator. Data were acquired on the scanner …

Optimization of subtraction brain perfusion SPECT with basal/acetazolamide consecutive acquisition

DS Lee, TH Lee, KM Kim, JK Chung… - The Korean Journal …, 1997 - koreascience.kr
This study investigated the method to adjust acquisition time (a) and injection dose (i) to
make the best basal and subtraction images in consecutive SPECT. Image quality was …

Influence of minimum count in brain perfusion SPECT: phantom and clinical studies

A Sugiura, M Onoguchi, T Shibutani… - Journal of Nuclear …, 2022 - Soc Nuclear Med
The count per pixel in brain perfusion SPECT images depends on the administered dose,
acquisition time, and patient condition and sometimes become low in daily clinical studies …

Comparison of methods of attenuation and scatter correction in brain perfusion SPECT

M Hayashi, J Deguchi, K Utsunomiya… - Journal of Nuclear …, 2005 - Soc Nuclear Med
Objective: The radioactivity count distribution in the brain must be determined accurately to
accurately measure cerebral blood flow (CBF). Scatter and attenuation are factors that …

Development of a practical image-based scatter correction method for brain perfusion SPECT: comparison with the TEW method

M Shidahara, H Watabe, KM Kim, T Kato… - European Journal of …, 2005 - Springer
Purpose An image-based scatter correction (IBSC) method was developed to convert scatter-
uncorrected into scatter-corrected SPECT images. The purpose of this study was to validate …