[PDF][PDF] 51Cr-EDTA biological half-life as an index of renal function

TG Brien, JA Fay - Journal of Nuclear Medicine, 1972 - Soc Nuclear Med
Since its introduction by Garnett, Parsons, and Veall in 1967 (7), MCr-EDTA has proved to
be a clinically useful radiopharmaceutical for the measure ment of glomerular filtration rate …

[CITATION][C] Measurement of glomerular filtration rate

WS Watson, M Muir, H Dobson… - Journal of Nuclear …, 1986 - Soc Nuclear Med
Russell (4) when comparing DTPA-GFR (Gates' method) and eight points plasma clearance
of ytterbium-169-DTPA. How ever, caution must be paid when Cr-Cl is taken as the gold …

A simplified determination of glomerular filtration rate with 99Tcm-DTPA

G Galli, V Rufini, G Meduri - Nuclear medicine communications, 1994 - journals.lww.com
Using 99 Tc m-diethylenetriaminepentaacetate (DTPA) an acceptable estimate of
glomerular filtration rate (GFR) can be obtained in adult patients by the equation GF …

Total plasma clearance of 51Cr-EDTA: variation with age and sex in normal adults

D Hamilton, P Riley, U Miola, D Mousa… - Nuclear medicine …, 2000 - journals.lww.com
Although inulin clearance measured during constant infusion is still considered the
reference method, single-injection of 51 Cr-EDTA with subsequent plasma sampling has …

Long-term precision of glomerular filtration rate measurements using 51Cr-EDTA plasma clearance

GM Blake, D Roe, CR Lazarus - Nuclear medicine …, 1997 - journals.lww.com
The long-term precision of chromium-51 ethylenediamine tetraacetic acid (51 Cr-EDTA)
measurements of glomerular filtration rate (GFR) was evaluated in a retrospective study of …

[PDF][PDF] Computation of glomerular filtration rate with Tc-99m DTPA: an in-house computer program

GF Gates - Journal of nuclear medicine, 1984 - Soc Nuclear Med
The glomerular filtration rate (GFR) can be computed fol lowing scintigraphic determination
of Tc-99m DTPA (diethy lenetriaminepentaacetic acid) uptake within the kidney (s) at the 2 …

Determination of Glomerular Filtration Rate with 51Cr, 58Co, 114mIn, 115mIn and 169Yb- Labelled EDTA and DTPA Complexes

G Molnár, I Pal, M Stützel, L Jaky - Dynamic Studies with …, 1971 - inis.iaea.org
[en] Some metal complexes are suitable for determination of the glomerular filtration rate
(GFR). A series of labelled EDTA and DTPA complexes have been produced during the last …

Accuracy of plasma sample methods for determination of glomerular filtration rate with99mTc-DTPA

K Itoh, S Tsushima, E Tsukamoto, N Tamaki - Annals of nuclear medicine, 2002 - Springer
The plasma sample method following a single injection of radioactive markers has been
proved to be simple and accurate for the determination of glomerular filtration rate (GFR) in …

113mIn-DTPA, a useful compound for the determination of glomerular filtration rate (GFR). The binding of 113mIn to DTPA and a comparison between GFR estimated …

RS Johansson, DK Falch - European Journal of Nuclear Medicine, 1978 - europepmc.org
For measurement of glomerular filtration rate the usefulness of diethyl traimino penta acic
(DTPA) labelled with 113mIndium has been explored. The labelling procedure is very …

Comparison of four commercial Tc-99m (Sn) DTPA preparations used for the measurement of glomerular filtration rate: concise communication.

JE Carlsen, ML Møller, JO Lund… - Journal of Nuclear …, 1980 - europepmc.org
To find a commercially available DTPA preparation that could be used for the measurement
of glomerular filtration rate (GFR), the plasma clearances of four different Tc-99m (Sn) DTPA …