[PDF][PDF] Correction and characterization of scattered events in three-dimensional PET using scanners with retractable septa
1: 0: 2.2.(B) Decay-correctedprojectionsthroughsequentialtwo-dimensionaland three-
dimensionalacquisitionsof slot phantom data. Notice the increasedscatter fraction and …
dimensionalacquisitionsof slot phantom data. Notice the increasedscatter fraction and …
A single scatter simulation technique for scatter correction in 3D PET
3D PET emission data acquired without interplane septa contain a component of scattered
radiation which may exceed 30% for brain scans and 50% for chest studies. In order to …
radiation which may exceed 30% for brain scans and 50% for chest studies. In order to …
Scatter modelling and correction strategies in fully 3-D PET
H Zaidi - Nuclear medicine communications, 2001 - journals.lww.com
PET offers the possibility of quantitative measurements of tracer concentration in vivo.
However, there are several issues that must be considered in order to fully realise this …
However, there are several issues that must be considered in order to fully realise this …
Scatter correction for three-dimensional PET based on an analytic model dependent on source and attenuating object
LG Hiltz, BTA McKee - Physics in Medicine & Biology, 1994 - iopscience.iop.org
Three-dimensional positron emission tomography admits a significant scatter fraction due to
the large aperture of the detectors, and requires accurate scatter subtraction. A scatter …
the large aperture of the detectors, and requires accurate scatter subtraction. A scatter …
New, faster, image-based scatter correction for 3D PET
CC Watson - … Record. 1999 Nuclear Science Symposium and …, 1999 - ieeexplore.ieee.org
The authors report on a new numerical implementation of the single-scatter simulation
scatter correction algorithm for 3D PET. Its primary advantage over the original …
scatter correction algorithm for 3D PET. Its primary advantage over the original …
Comparative evaluation of scatter correction in 3D PET using different scatter-level approximations
I Polycarpou, K Thielemans, R Manjeshwar… - Annals of nuclear …, 2011 - Springer
Abstract Objective In 3D PET, scatter of the gamma photons is one of the most significant
physical factors which degrades not only image quality but also quantification. The currently …
physical factors which degrades not only image quality but also quantification. The currently …
[PDF][PDF] Simultaneous emission and transmission measurements for attenuation correction in whole-body PET
The method for simultaneously acquiringemission and trans missioncoincidencedata is an
extensionofthe sinogramwindow-@ 6 ing technique (15— 17) which has been used to …
extensionofthe sinogramwindow-@ 6 ing technique (15— 17) which has been used to …
Scatter correction in 3-D PET
MJ Lercher, K Wienhard - IEEE transactions on medical …, 1994 - ieeexplore.ieee.org
Modern multiring positron emission tomographs allow the acquisition of 3-D data sets to
increase their sensitivity. A substantial part of this data is due to scattered radiation. The …
increase their sensitivity. A substantial part of this data is due to scattered radiation. The …
Effect of scatter from radioactivity outside of the field of view in 3D PET
V Sossi, JS Barney, R Harrison… - IEEE transactions on …, 1995 - ieeexplore.ieee.org
The contribution of the scattered events originating from radioactivity outside the tomograph
field of view (ROFOV) is treated differently by different scatter correction algorithms. Using …
field of view (ROFOV) is treated differently by different scatter correction algorithms. Using …
Detector efficiency and Compton scatter in fully 3D PET
JM Ollinger - IEEE transactions on nuclear science, 1995 - ieeexplore.ieee.org
Variations in detector efficiency induce significant artifacts in reconstructed images unless
accurate normalization methods are used. Scattered events are detected with significantly …
accurate normalization methods are used. Scattered events are detected with significantly …