[PDF][PDF] Anatomic standardization: linear scaling and nonlinear warping of functional brain images

S Minoshima, RA Koeppe, KA Frey… - Journal of Nuclear …, 1994 - Soc Nuclear Med
An automated method was proposed for anatomic standardiza tion of PET scans in three
dimensions, which enabled objective intersubject and cross-group comparisons of …

[PDF][PDF] Global spatial normalization of human brain using convex hulls

JL Lancaster, PT Fox, H Downs… - Journal of Nuclear …, 1999 - Soc Nuclear Med
MR images. Conclusion: The globalfeaturesof CH-spatially normalized brain images
(position, orientation and size) were consistentlytransformedto matchthe TalairachAtlas in …

Statistical brain mapping of 18F-FDG PET in Alzheimer's disease: validation of anatomic standardization for atrophied brains

K Ishii, F Willoch, S Minoshima, A Drzezga… - Journal of Nuclear …, 2001 - Soc Nuclear Med
Despite the increased use of statistical mapping to detect brain functional changes in
Alzheimer's disease (AD), potential artifacts introduced by stereotactic anatomic …

[PDF][PDF] An automated method for rotational correction and centering of three-dimensional functional brain images

S Minoshima, KL Berger, KS Lee… - Journal of Nuclear …, 1992 - Soc Nuclear Med
Division ofNuclear Medicine, Department oflnternal Medicine, UniversityofMichigan, Ann
Arbor, Michigan to the registration of two similar but nonidentical images from the same …

Correction of partial-volume effect for PET striatal imaging: fast implementation and study of robustness

V Frouin, C Comtat, A Reilhac… - Journal of Nuclear …, 2002 - Soc Nuclear Med
PET imaging of D2 receptors or 18F-l-dopa metabolism are reference protocols to follow and
study neurodegenerative diseases, but the accuracy of striatal PET imaging is limited by the …

Functional and structural synergy for resolution recovery and partial volume correction in brain PET

M Shidahara, C Tsoumpas, A Hammers, N Boussion… - Neuroimage, 2009 - Elsevier
Purpose: Positron Emission Tomography (PET) has the unique capability of measuring brain
function but its clinical potential is affected by low resolution and lack of morphological …

A Standardized [18F]-FDG-PET Template for Spatial Normalization in Statistical Parametric Mapping of Dementia

PA Della Rosa, C Cerami, F Gallivanone, A Prestia… - Neuroinformatics, 2014 - Springer
Abstract [18 F]-fluorodeoxyglucose (FDG) Positron Emission Tomography (PET) is a widely
used diagnostic tool that can detect and quantify pathophysiology, as assessed through …

Evaluation of anatomy based reconstruction for partial volume correction in brain FDG-PET

K Baete, J Nuyts, K Van Laere, W Van Paesschen… - Neuroimage, 2004 - Elsevier
FDG-PET contributes to the diagnosis and management of neurological diseases. In some
of these diseases, pathological gray matter (GM) areas may have a reduced FDG uptake …

[PDF][PDF] A rapid and accurate method to realign PET scans utilizing image edge information

JLR Andersson - Journal of nuclear medicine, 1995 - Soc Nuclear Med
Movementduringor between PET examinationsIs a common and serious problem.
Consequently, there is a great need for rapid, accurate and robust methods to realign image …

Warping of a computerized 3-D atlas to match brain image volumes for quantitative neuroanatomical and functional analysis

AC Evans, W Dai, DL Collins… - Medical Imaging V …, 1991 - spiedigitallibrary.org
We describe the implementation, experience and preliminary results obtained with a 3-D
computerized brain atlas for topographical and functional analysis of brain sub-regions. A …