Estimating an attenuation map from measured scatter for 180o cardiac SPECT
1357 Objectives Attenuation correction is required for accurate reconstruction of cardiac
SPECT images, however inclusion of an accurate attenuation map is essential. This work …
SPECT images, however inclusion of an accurate attenuation map is essential. This work …
A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models
MK O'connor, B Kemp, F Anstett, P Christian… - Journal of nuclear …, 2002 - Elsevier
Background. Our goal was to evaluate the ability of current commercially available
attenuation compensation (AC) techniques to correct for the effects of attenuation, scatter …
attenuation compensation (AC) techniques to correct for the effects of attenuation, scatter …
Techniques for generating attenuation map using cardiac SPECT emission data only: a systematic review
To reliably interpret and perform quantitative analysis, attenuation correction for cardiac
single-photon emission computed tomography (SPECT) is fundamental. Thus, knowledge of …
single-photon emission computed tomography (SPECT) is fundamental. Thus, knowledge of …
Correction for attenuation and scatter in SPECT
BF Hurton - Rev. med. nucl. Alasbimn j, 2002 - pesquisa.bvsalud.org
Basic consideration of SPECT reconstruction using filtered back projection (FBP) ignores the
effects of attenuation and assumes that all detected photons originate from points along the …
effects of attenuation and assumes that all detected photons originate from points along the …
A study of apparent apical defects in attenuation corrected cardiac SPECT
C Bai, GL Zeng, DJ Kadrmas… - IEEE Transactions on …, 1999 - ieeexplore.ieee.org
There are a number of factors that affect the intensity of the apical region in cardiac SPECT
images, which sometime lead to apparent defects in this region. In some patient studies …
images, which sometime lead to apparent defects in this region. In some patient studies …
SPECT quantification: a simplified method of attenuation and scatter correction for cardiac imaging.
JR Galt, SJ Cullom, EV Garcia - Journal of Nuclear Medicine: official …, 1992 - europepmc.org
The quantitative and visual interpretation of SPECT myocardial perfusion images is limited
by physical factors such as photon attenuation, Compton scatter, and finite resolution effects …
by physical factors such as photon attenuation, Compton scatter, and finite resolution effects …
A differential attenuation method for simultaneous estimation of SPECT activity and attenuation distributions
MS Kaplan, DR Haynor, H Vija - IEEE Transactions on Nuclear …, 1999 - ieeexplore.ieee.org
A penalized weighted least squares (PWLS) reconstruction algorithm is described that
simultaneously estimates activity and attenuation distributions from emission sinogram data …
simultaneously estimates activity and attenuation distributions from emission sinogram data …
[PDF][PDF] Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT
Methods: Monte Carlo simulationsand real acquisitionof a" mTc cardiac phantom were
performed under comparable conditions. Simulated and acquired data were reconstructed …
performed under comparable conditions. Simulated and acquired data were reconstructed …
[PDF][PDF] Correction of nonuniform attenuation in cardiac SPECT imaging
BMW Tsui, GT Gullberg, ER Edgerton… - Journal of Nuclear …, 1989 - Soc Nuclear Med
J Nuci Med 30: 497— 507, 1989 hile single photon emission computed tomogra phy
(SPECT) imaging has become a routine clinical procedure in nuclear medicine, the problem …
(SPECT) imaging has become a routine clinical procedure in nuclear medicine, the problem …
[PDF][PDF] Javabased plugin for tomographic reconstruction for SPECT data
In this work the approach for obtaining the attenuation maps for cardiac SPECT was the
estimation directly from the emission data, without transmission imaging, based on …
estimation directly from the emission data, without transmission imaging, based on …
Related searches
- attenuation map measured scatter
- cardiac spect attenuation correction
- cardiac spect collimator response
- cardiac spect consistency conditions
- cardiac spect relative impact
- cardiac spect multicenter evaluation
- consistency conditions attenuation correction
- spect activity attenuation distributions
- scatter correction spect quantification
- scatter correction cardiac imaging
- spect quantification cardiac imaging
- nonuniform attenuation spect imaging
- correction for attenuation scatter in spect