Estimating an attenuation map from measured scatter for 180o cardiac SPECT

S Cade, A Bousse, S Arridge, M Evans, B Hutton - 2010 - Soc Nuclear Med
1357 Objectives Attenuation correction is required for accurate reconstruction of cardiac
SPECT images, however inclusion of an accurate attenuation map is essential. This work …

A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models

MK O'connor, B Kemp, F Anstett, P Christian… - Journal of nuclear …, 2002 - Elsevier
Background. Our goal was to evaluate the ability of current commercially available
attenuation compensation (AC) techniques to correct for the effects of attenuation, scatter …

Techniques for generating attenuation map using cardiac SPECT emission data only: a systematic review

GF Tadesse, P Geramifar, EM Tegaw, MR Ay - Annals of nuclear medicine, 2019 - Springer
To reliably interpret and perform quantitative analysis, attenuation correction for cardiac
single-photon emission computed tomography (SPECT) is fundamental. Thus, knowledge of …

Correction for attenuation and scatter in SPECT

BF Hurton - Rev. med. nucl. Alasbimn j, 2002 - pesquisa.bvsalud.org
Basic consideration of SPECT reconstruction using filtered back projection (FBP) ignores the
effects of attenuation and assumes that all detected photons originate from points along the …

A study of apparent apical defects in attenuation corrected cardiac SPECT

C Bai, GL Zeng, DJ Kadrmas… - IEEE Transactions on …, 1999 - ieeexplore.ieee.org
There are a number of factors that affect the intensity of the apical region in cardiac SPECT
images, which sometime lead to apparent defects in this region. In some patient studies …

SPECT quantification: a simplified method of attenuation and scatter correction for cardiac imaging.

JR Galt, SJ Cullom, EV Garcia - Journal of Nuclear Medicine: official …, 1992 - europepmc.org
The quantitative and visual interpretation of SPECT myocardial perfusion images is limited
by physical factors such as photon attenuation, Compton scatter, and finite resolution effects …

A differential attenuation method for simultaneous estimation of SPECT activity and attenuation distributions

MS Kaplan, DR Haynor, H Vija - IEEE Transactions on Nuclear …, 1999 - ieeexplore.ieee.org
A penalized weighted least squares (PWLS) reconstruction algorithm is described that
simultaneously estimates activity and attenuation distributions from emission sinogram data …

[PDF][PDF] Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT

G El Fakhri, I Buvat, H Benali… - Journal of Nuclear …, 2000 - Soc Nuclear Med
Methods: Monte Carlo simulationsand real acquisitionof a" mTc cardiac phantom were
performed under comparable conditions. Simulated and acquired data were reconstructed …

[PDF][PDF] Correction of nonuniform attenuation in cardiac SPECT imaging

BMW Tsui, GT Gullberg, ER Edgerton… - Journal of Nuclear …, 1989 - Soc Nuclear Med
J Nuci Med 30: 497— 507, 1989 hile single photon emission computed tomogra phy
(SPECT) imaging has become a routine clinical procedure in nuclear medicine, the problem …

[PDF][PDF] Javabased plugin for tomographic reconstruction for SPECT data

MA Andrade, MVS Costa, AMM Silva - Med Phys, 2006 - Citeseer
In this work the approach for obtaining the attenuation maps for cardiac SPECT was the
estimation directly from the emission data, without transmission imaging, based on …