Assessment of Rapid Changes in Renal Blood Flow with 191mIr, an Ultra-Short-Lived Radionuclide

ST Treves, AB Packard, LCT Fung - Journal of Nuclear Medicine, 2004 - Soc Nuclear Med
We investigated the feasibility of using 191mIr (half-life, 5 s) to measure rapid dynamic
alterations in differential renal blood flow. Methods: A nonobstructive constant renal pelvic …

191Os/191mIr-generator for studying arterial blood flow in experimental animal models.

KJ Kairemo, MS Kestilä, S Savolainen… - Journal of Nuclear …, 1994 - europepmc.org
Iridium-191m (191mIr, t1/2= 4.96 sec), an ultra-short lived tracer, has turned out to be
suitable for gamma imaging. It can be obtained in high yields from an 191Os/191mIr …

191mIr: distribution and retention in animal experiments

KJ Kairemo, MS Kestilä, RI Svahn… - Nuklearmedizin. Nuclear …, 1995 - europepmc.org
Ultrashort-lived tracer 191mIr (T1/2= 4.92 s) can be obtained with a high yield from an
191Os/191mIr generator with a low 191Os breakthrough. It was eluated directly into the tail …

Rapid renal single-photon emission tomography by continuous infusion of iridium-191m

ST Treves, L Fung, AB Packard - European journal of nuclear medicine, 1999 - Springer
Continuous infusion of iridium-191m (t 1/2 á= á5ás), produced with an 191 Os/191m Ir
generator, was used to obtain rapid high-resolution single-photon emission tomography …

Noninvasive measurement of absolute renal perfusion by contrast medium-enhanced magnetic resonance imaging

X Montet, MK Ivancevic, J Belenger… - Investigative …, 2003 - journals.lww.com
Objective: The aim of this study was to validate the quantification of absolute renal perfusion
(RP) determined by dynamic magnetic resonance imaging (MRI) and contrast media using …

Dynamic renal scanning using 99mTc-MAG-3 in man

CL Maini, P Antonacci, A Sargiotto… - European journal of …, 1989 - Springer
Abstract 99m Tc-labelled mercapto-acetyltriglycine (MAG-3) has recently been proposed as
an ortho-iodohippurate (OIH) substitute for dynamic renal imaging. Experience with MAG-3 …

Determination of the renal blood flow in macro-and microcirculation by means of pulse inversion imaging

T Schlosser, C Veltmann, S Lohmaier… - Rofo: Fortschritte auf …, 2004 - europepmc.org
Purpose To evaluate whether real-time and intermittent pulse inversion technology (PI)
allows the analysis of blood flow in renal macro-and microcirculation. Materials and methods …

Relative renal blood flow measurements with Rb-82 and a hybrid gamma camera using a pig model

PH Pretorius, LCT Fung, CP Schell… - IEEE transactions on …, 2005 - ieeexplore.ieee.org
We have successfully demonstrated with chronically implanted blood flow probes in a pig
model that renal uptake of Rb-82 is indeed sensitive to acute renal blood flow changes. Two …

Quality of dynamic radionuclide renal imaging: multicentre evaluation using a functional renal phantom

JO Heikkinen, JT Kuikka, AKA Ahonen… - Nuclear medicine …, 2001 - journals.lww.com
The aim of this study was to evaluate the quality of dynamic radionuclide renal imaging in
Finland. Nineteen nuclear medicine departments participated. A functional renal phantom …

First-pass renal perfusion imaging using MS-325, an albumin-targeted MRI contrast agent

PV Prasad, J Cannillo, DR Chavez… - Investigative …, 1999 - journals.lww.com
Abstract Prasad PV, Cannillo J, Chavez DR, et al. First-pass renal perfusion imaging using
MS-325, an albumin-targeted MRI contrast agent. Invest Radiol 1999; 34: 566–571 …