[PDF][PDF] Optimized collimators for scintillation cameras

S Swann, D Palmer, L Kaufman, CB Lim… - Journal of Nuclear …, 1976 - Soc Nuclear Med
METHODS While both lead and tantalum tubes are available, we have found the latter to be
the material of choice. The relevant physical characteristics of the two ele ments are …

[PDF][PDF] Collimator performance for scintillation camera systems

VA Brookeman, TJ Bauer - Journal of Nuclear Medicine, 1973 - Soc Nuclear Med
MATERIALS AND METHODS Systems description. The imaging systems studied were a
Pho/Gamma III scintillation camera, initially with conventional S-11 phototubes and later with …

[PDF][PDF] A line-source phantom for testing the performance of scintillation cameras

E Jahns, GJ Hine - Journal of Nuclear Medicine, 1967 - Soc Nuclear Med
METHOD A geometrical phantom3 (Fig. 1) has been constructed that is easy to re produce.
With a circular saw grooves are cut into a 10 mm thick rectangular Lucite plate 30-by 30-cm …

Scintillation camera collimators

G Muehllehner - Nuclear Medicine, Ultrasonics, and Thermography, 1980 - Springer
A collimator is essentially a block of lead larger than the detector, containing an
arrangement of holes which allows gamma rays to pass through from a specified direction …

Collimator technology and advancements

RJ Wilson - Journal of Nuclear Medicine Technology, 1988 - Soc Nuclear Med
This is the final article in a four-part continuing education series on scintillation camera
technology. After studying this article the reader should be able to: 1) understand the …

[PDF][PDF] Scintillation camera with multichannel collimators

HO Anger - 1964 - escholarship.org
The design and use of parallel-channel collimators with the s cintillatio!'.. camera are
described. Equations for calculating the optimum hole diameter, length,. and septal …

Comparative assessment of scintillation camera performance

JL Moretti, B Mensch, A Guey, A Desgrez - Radiology, 1976 - pubs.rsna.org
The performance characteristics of 5 scintillation cameras were compared: Searle 19, Searle
37, Ohio Nuclear, Picker 2C and Toshiba GCA 202. Inherent characteristics including spatial …

Collimator selection for scintillation camera brain scanning

FW Wilcox, WH Edgar, WR Brown - Journal of Nuclear Medicine, 1969 - Soc Nuclear Med
We have performed studies using the 4,000-hole and 1,000-hole collimator provided with
the Nuclear Chicago Pho-Gamma III scintillation camera and a@ mTcsource similar to that …

An image tube scintillation camera for use with radioactive isotopes emitting low-energy photons

MM Ter-Pogossian, WF Niklas, J Ball, JO Eichling - Radiology, 1966 - pubs.rsna.org
Many radioactive isotopes decay with the emission of low-energy photons, which are either
(a) gamma rays or (b) x rays emitted subsequent to electron capture or internal conversion. It …

[PDF][PDF] Clinical efficacy of a large-field-of-view scintillation camera

JA Burdine, PH Murphy - Journal of Nuclear Medicine, 1975 - Soc Nuclear Med
MATERIALS AND METHODS The LFOV has 37 photomultiplier tubes with a useful field of
view of 15.25 in. using parallel-hole collimation. Several low-energy collimators, both …