The utility of technetium-99m DTPA inhalational scans in artificially ventilated patients.

SP Butler, PO Alderson, RL Greenspan… - Journal of Nuclear …, 1990 - europepmc.org
Technetium-99m diethylenetriaminepentaacetic acid ([99mTc] DTPA) radioaerosol scans
performed on 21 consecutive artificially ventilated patients were compared to 50 similar …

Ventilation scanning with technetium labeled aerosols DTPA or sulfur colloid?

G COATES, M DOLOVICH, D KOEHLER… - Clinical nuclear …, 1985 - journals.lww.com
We have compared the distribution in the lungs of submicronic aerosols of either Tc-99m
sulfur colloid or Tc-99m DTPA immediately after inhalation with the distribution 20 minutes …

Mismatch between99mTc-DTPA aerosol and81mKr lung ventilation scintigraphy: a pitfall of radionuclide imaging

H Hoshi, S Dadparvar, R Promisloff… - European journal of …, 1990 - Springer
Pulmonary ventilation and perfusion scintigraphies were performed using 99m Tc-MAA, 81m
Kr, and 99m Tc-DTPA aerosol in a patient with asthma. Lung perfusion scintigraphy and …

Clinical comparison of a new Tc-99m DTPA delivery system with Kr-81m

JP Finn, MJ Myers, KM Nair, JP Lavender - J. Nucl. Med.;(United States), 1984 - osti.gov
Satisfactory agents for ventilation imaging are not widely available. Access to Kr-81m is
limited and image quality with Xe-133 is poor, so attention is being focused on radioaerosols …

Scintigraphy of pulmonary ventilation with 99mTc-DTPA radio-aerosol. I. Semiotics of the static images

CL Maini, MG Bonetti, A Giordano, R Pistelli… - La Radiologia …, 1986 - europepmc.org
Papers on deposition pattern analyses of radio-aerosol lung scans are few and not easy to
interpret as there is a general lack of technical standardization and the number of patients …

Ventilation scintigraphy of the lung with 99mTc-DTPA or with 99mTc-sulfur colloid?

D Köhler, G Coates, M Dolovich… - Nuklearmedizin …, 1983 - europepmc.org
Ventilation scintigraphy of the lung, obtained with sufficiently small 99mTc-labelled aerosol
particles, provides an image of ventilation distribution that is acceptable in clinical routine …

[CITATION][C] Delivery Efficiency of Technetium-99m DTPA Aerosol—Reply

SA Sirr, F Gramith - Journal of Nuclear Medicine, 1986 - Soc Nuclear Med
TO THE EDITOR: Lung ventilation imaging employing radioaerosols of technetium-99m
diethylenetriaminepentaa cetic acid ([99mTCJDTPA) h@ now become established as an …

Comparison of Lung Ventilation Scan Using Technegas and Aerosol

YH Choi, SE Kim, DS Lee, JK Chung… - The Korean Journal …, 1990 - koreascience.kr
Pulmonary embolism demands rapid and accurate diagnosis. And ventilation imaging has
greatly improved the diagnostic accuracy of pulmonary embolism in addition to perfusion …

An improved technique for inhalation imaging

N Adiseshan - Clinical Nuclear Medicine, 1982 - journals.lww.com
Because of several limitations associated with conventional ventilation scintigraphy using
radioactive gases, an alternative method appears desirable. This paper describes in detail …

[CITATION][C] Delivery efficiency of technetium-99m DTPA aerosol

RC Smart, NR Lyons, RG McLean - Journal of Nuclear Medicine, 1986 - Soc Nuclear Med
TO THE EDITOR: Lung ventilation imaging employing radioaerosols of technetium-99m
diethylenetriaminepentaa cetic acid ([99mTCJDTPA) h@ now become established as an …