Biodistribution and safety of 18F-FP-R01-MG-F2 knottin PET tracer in patients with pancreatic cancer

R Nakamoto, H Duan, V Ferri, N Hatami, M Goel… - 2021 - Soc Nuclear Med
1008 Purpose: 18 F-FP-R 0 1-MG-F2 is a novel cystine knot peptide (knottin) PET tracer that
selectively binds to human integrin α v β 6. This integrin cell surface receptor is over …

Pilot-phase PET/CT study targeting integrin αvβ6 in pancreatic cancer patients using the cystine-knot peptide–based 18F-FP-R01-MG-F2

R Nakamoto, V Ferri, H Duan, N Hatami, M Goel… - European Journal of …, 2022 - Springer
Purpose A novel cystine-knot peptide–based PET radiopharmaceutical, 18 F-FP-R 0 1-MG-
F2 (knottin), was developed to selectively bind to human integrin α v β 6 which is …

18F-Fluorobenzoate–labeled cystine knot peptides for PET imaging of integrin αvβ6

BJ Hackel, RH Kimura, Z Miao, H Liu… - Journal of Nuclear …, 2013 - Soc Nuclear Med
Integrin αvβ6 is a cell surface receptor minimally expressed by healthy tissue but elevated in
lung, colon, skin, ovarian, cervical, and pancreatic cancers. A molecular PET agent for …

[HTML][HTML] PET imaging of integrin positive tumors using 18F labeled knottin peptides

S Liu, H Liu, G Ren, RH Kimura, JR Cochran… - Theranostics, 2011 - ncbi.nlm.nih.gov
Purpose: Cystine knot (knottin) peptides, engineered to bind with high affinity to integrin
receptors, have shown promise as molecular imaging agents in living subjects. The aim of …

A radiofluorinated divalent cystine knot peptide for tumor PET imaging

L Jiang, RH Kimura, X Ma, Y Tu, Z Miao… - Molecular …, 2014 - ACS Publications
A divalent knottin containing two separate integrin binding epitopes (RGD) in the adjacent
loops, 3-4A, was recently developed and reported in our previous publication. In the current …

An Engineered Knottin Peptide Labeled with 18F for PET Imaging of Integrin Expression

Z Miao, G Ren, H Liu, RH Kimura, L Jiang… - Bioconjugate …, 2009 - ACS Publications
Knottins are small constrained polypeptides that share a common disulfide-bonded
framework and a triple-stranded β-sheet fold. Previously, directed evolution of the Ecballium …

In vivo characterization of proliferation for discriminating cancer from pancreatic pseudotumors

K Herrmann, F Eckel, S Schmidt… - Journal of nuclear …, 2008 - Soc Nuclear Med
We have determined the ability of PET with the thymidine analog 3′-deoxy-3′-18F-
fluorothymidine (FLT) to detect pancreatic cancer and to differentiate malignant from benign …

68Ga-Labeled Cystine Knot Peptide Targeting Integrin αvβ6 for Lung Cancer PET Imaging

J Ren, S Zhu, G Zhang, X Tan, L Qiu, J Lin… - Molecular …, 2022 - ACS Publications
Integrin αvβ6 has been considered as a promising biomarker for lung cancer, and its
expression is often related to poor prognosis. An αvβ6-binding cystine knot peptide R01-MG …

Evaluation of 3-deoxy-3-18fluorothymidine PET (FLT-PET) for the detection of pancreatic cancer–Comparison to FDG-PET/CT

K Herrmann, M Erkan, F Eckel, BJ Krause, HJ Wester… - 2009 - Soc Nuclear Med
1746 Objectives Evaluation of the test performance of PET with the proliferation marker FLT
compared to FDG for detection of pancreatic cancer. Methods In this ongoing clinical trial, 27 …

[HTML][HTML] SPECT/CT Imaging, Biodistribution and Radiation Dosimetry of a 177Lu-DOTA-Integrin αvβ6 Cystine Knot Peptide in a Pancreatic Cancer Xenograft Model

S Sachindra, T Hellberg, S Exner, S Prasad… - Frontiers in …, 2021 - frontiersin.org
Introduction Pancreatic ductal adenocarcinoma (PDAC) is one of the most aggressive
malignant neoplasms, as many cases go undetected until they reach an advanced stage …