[PDF][PDF] The effect of flow on technetium-99m-teboroxime (SQ30217) and thallium-201 extraction and retention in rabbit heart

RC Marshall, EM Leidholdt, DY Zhang… - Journal of Nuclear …, 1991 - Soc Nuclear Med
Preparation of isovolumic retrograde blood-perfused rabbit hearts was similar to that
previously reported (12, 13). Briefly, after administration of 10 mg of sodium heparin and 200 …

[PDF][PDF] Myocardial extraction of technetium-99m-[2-(1-methoxybutyl) isonitrile] in the isolated rabbit heart: a myocardial perfusion agent with high extraction and stable …

ST Dahlberg, DJ Meerdink, MP Gilmore… - Journal of Nuclear …, 1993 - Soc Nuclear Med
METhODS Surgeryand Perfusion Isolated, isovolumically-contractingrabbit hearts were per
fused using established methods (2). Male New Zealand white rabbits (1.5 — 2.5 kg) were …

[PDF][PDF] Measurement of myocardial blood flow using a co-injection technique for technetium-99m-teboroxime, technetium-96-sestamibi and thallium-201

RJ Di Rocco, WL Rumsey, BL Kuczynski… - Journal of Nuclear …, 1992 - Soc Nuclear Med
Radiopharmaceutical Preparation Technetium-99m-teboroxime was prepared as previously
de scribed (11). Thallium-201 was obtained from Dupont. The@ Tc was produced by …

[PDF][PDF] Comparison of hypoxia and ouabain effects on the myocardial uptake kinetics of technetium-99m hexakis 2-methoxyisobutyl isonitrile and thallium-201

DJ Meerdink, JA Leppo - Journal of nuclear medicine, 1989 - Soc Nuclear Med
Surgery and perfusion. An isolated, isovolumetrically-con tracting rabbit heart preparation,
utilizing methods previously describedin detail (7-9), wasusedforallexperiments. Briefly …

[PDF][PDF] Myocardial clearance kinetics of technetium-99m-SQ30217: a marker of regional myocardial blood flow

RE Stewart, M Schwaiger, GD Hutchins… - Journal of Nuclear …, 1990 - Soc Nuclear Med
METHODS Open-Chested Heart Preparation Ten mongrel dogs of both sexes weighing
12— 25kg were anesthetized with iv pentobarbital (30 mg/kg). Each dog was intubated and …

Uptake of technetium-99m-teboroxime in cultured myocardial cells: comparison with thallium-201 and technetium-99m-sestamibi.

JC Maublant, N Moins, P Gachon… - Journal of Nuclear …, 1993 - europepmc.org
The effects of metabolic inhibition on the uptake of 99mTc-teboroxime were assessed in
cultured myocardial cells and compared with 201Tl and 99mTc-sestamibi. Metabolic …

[PDF][PDF] Myocardial uptake of thallium-201 augmented with bicarbonate: concise communication

KR Hetzel, BR Westerman, JL Quinn… - Journal of Nuclear …, 1977 - Soc Nuclear Med
MATERIALSAND METHODS Two groups of three rabbits each, weighing 2 kg, were injected
with either 25@@ Ciof thallium-201@ or 25@ Ciof thallium-20i with 0.7 mEq/kg sodium …

Comparative myocardial extraction of two technetium-labeled BATO derivatives (SQ30217, SQ32014) and thallium.

JA Leppo, DJ Meerdink - Journal of Nuclear Medicine: Official …, 1990 - europepmc.org
The transcapillary exchange of a new class of 99mTc-labeled compounds (BATO) were
compared to 201Tl in isolated, blood perfused rabbit hearts. During variable blood flow (0.15 …

[PDF][PDF] Hexakis (2-methoxy isobutylisonitrile) technetium-99m and thallium-201 chloride: uptake and release in cultured myocardial cells

JC Maublant, P Gachon, N Moins - Journal of nuclear medicine, 1988 - Soc Nuclear Med
Hexakis (2-methoxy ¡ sobutylisonitrile) technetium-99m ([" TcJMIBI), a new tracer of
myocardial blood flow, was compared with 201TICI in cultures of myocardial cells of …

Extraction and retention of technetium-99m Q12, technetium-99m sestamibi, and thallium-201 in isolated rat heart during coronary acidemia

AJ McGoron, MC Gerson, DS Biniakiewicz… - European journal of …, 1997 - Springer
Technetium-99m Q12 and 99m Tc-sestamibi are cationic lipophilic myocardial perfusion
imaging tracers. Because myocardium in areas of ischemia becomes acidotic, experiments …