Performance of scintillation cameras

RP Grenier - Journal of Nuclear Medicine, 1976 - Soc Nuclear Med
jIUn/LETTERS TO THE EDITOR Page 1 Performance of Scintillation Cameras A recent
letter by Hine and Paras (I) deserves a word of comment because it omits important data on …

[PDF][PDF] A new autofluoroscopic camera

WH Beierwaltes, GM Brown, LW Jones… - Journal of Nuclear …, 1967 - Soc Nuclear Med
The ideal properties of a scintillation camera system for nuclear medicine would be: 1) 100%
efficiency in detecting photons (X-rays or gamma-rays) enter ing its aperture, together with …

[PDF][PDF] Preliminary imaging studies with a large crystal scintillation camera

M Hayes - Journal of Nuclear Medicine, 1971 - Soc Nuclear Med
mn/PRELIMINARY NOTE Page 1 A limitation of the standard scintillation camera is its field
size. At present there are at least three gen eral approaches to increasing useable field size …

Comparative assessment of scintillation camera performance

JL Moretti, B Mensch, A Guey, A Desgrez - Radiology, 1976 - pubs.rsna.org
The performance characteristics of 5 scintillation cameras were compared: Searle 19, Searle
37, Ohio Nuclear, Picker 2C and Toshiba GCA 202. Inherent characteristics including spatial …

Collimator technology and advancements

RJ Wilson - Journal of Nuclear Medicine Technology, 1988 - Soc Nuclear Med
This is the final article in a four-part continuing education series on scintillation camera
technology. After studying this article the reader should be able to: 1) understand the …

[PDF][PDF] A line-source phantom for testing the performance of scintillation cameras

E Jahns, GJ Hine - Journal of Nuclear Medicine, 1967 - Soc Nuclear Med
METHOD A geometrical phantom3 (Fig. 1) has been constructed that is easy to re produce.
With a circular saw grooves are cut into a 10 mm thick rectangular Lucite plate 30-by 30-cm …

[PDF][PDF] Collimator performance for scintillation camera systems

VA Brookeman, TJ Bauer - Journal of Nuclear Medicine, 1973 - Soc Nuclear Med
MATERIALS AND METHODS Systems description. The imaging systems studied were a
Pho/Gamma III scintillation camera, initially with conventional S-11 phototubes and later with …

[CITATION][C] Nuclear medicine: 100 years in the making

HN Wagner - Journal of Nuclear Medicine, 1996 - Soc Nuclear Med
Today nuclear medicine is returning to the operating room. New devices include a beta
detector system being developed at UCLA. At the University of Tokyo, surgeons used a …

[PDF][PDF] Clinical efficacy of a large-field-of-view scintillation camera

JA Burdine, PH Murphy - Journal of Nuclear Medicine, 1975 - Soc Nuclear Med
MATERIALS AND METHODS The LFOV has 37 photomultiplier tubes with a useful field of
view of 15.25 in. using parallel-hole collimation. Several low-energy collimators, both …

Performance and acceptance testing of scintillation cameras for SPECT

RJ English, RE Zimmerman - Journal of Nuclear Medicine …, 1988 - Soc Nuclear Med
This is the third in a series of four continuing education articles related to the characteristics
of the scintillation camera. Upon completion of this article, the reader should be able to: 1) …