[PDF][PDF] Technetium-99m-tetrofosmin myocardial imaging: a comparison with thallium-201 and angiography
P Rigo, B Leclercq, R Itti, A Lahiri… - Journal of Nuclear …, 1994 - Soc Nuclear Med
Technetium-99m-Tetrofosmin Myocardial Imaging: A Comparison with Thallium-201 and
Angiography Page 1 (CAD) (1). Indeed, this technique, primarily developed using 20111,has …
Angiography Page 1 (CAD) (1). Indeed, this technique, primarily developed using 20111,has …
Tomographic myocardial imaging with technetium-99m tetrofosmin: Comparison with tetrofosmin and Thallium planar imaging and with angiography
T Benoit, D Vivegnis, A Lahiri, R Itti… - European heart …, 1996 - academic.oup.com
Technetium-99m tetrofosmin is a new myocardial imaging agent with improved handling
and kinetic characteristics. The purpose of this study was to compare the ability of planar …
and kinetic characteristics. The purpose of this study was to compare the ability of planar …
Planar and tomographic imaging with technetium 99m-labeled tetrofosmin: correlation with thallium 201 and coronary angiography
J Heo, V Cave, V Wasserleben… - Journal of Nuclear …, 1994 - Springer
This study compared the results of planar and single-photon emission computed
tomographic (SPECT) imaging with tetrofosmin with those of 201 Tl and coronary …
tomographic (SPECT) imaging with tetrofosmin with those of 201 Tl and coronary …
Accuracy of 99mTc-tetrofosmin myocardial tomography in the evaluation of coronary artery disease
S Azzarelli, AR Galassi, R Foti, C Mammana… - Journal of Nuclear …, 1999 - Elsevier
Background. Technetium 99m-labeled myocardial agents have been proposed as an
alternative to thallium 201. The aim of this study was to assess retrospectively the accuracy …
alternative to thallium 201. The aim of this study was to assess retrospectively the accuracy …
[PDF][PDF] Comparison between thallium-201, technetium-99m-sestamibi and technetium-99m-teboroxime planar myocardial perfusion imaging in detection of coronary …
R Taillefer, R Lambert, R Essiambre… - Journal of Nuclear …, 1992 - Soc Nuclear Med
From the Department ofNuclear Medicine and Division ofCardiology, HÃpitalHÃtel-Dieu de
Montré al, Université de Montré al, Montré al, Canada mill stress tests with 201T1 …
Montré al, Université de Montré al, Montré al, Canada mill stress tests with 201T1 …
Direct comparison of technetium 99m—sestamibi and technetium 99m—tetrofosmin cardiac single photon emission computed tomography in patients with coronary …
Background. Technetium 99m-labeled sestamibi and tetrofosmin tomography have shown
high diagnostic accuracy in the detection of coronary artery disease (CAD). However, few …
high diagnostic accuracy in the detection of coronary artery disease (CAD). However, few …
Comparison of myocardial perfusion imaging with technetium-99m tetrofosmin versus thallium-201 in coronary artery disease
BS Sridhara, S Braat, P Rigo, R Itti, P Cload… - The American journal of …, 1993 - Elsevier
Abstract Technetium-99m (To-99m) tetrofosmin, a new myocardial perfusion imaging agent,
was evaluated at exercise and rest in 50 patients with documented coronary artery disease …
was evaluated at exercise and rest in 50 patients with documented coronary artery disease …
Myocardial perfusion imaging and dynamic analysis with technetium-99m tetrofosmin.
K Nakajima, J Taki, N Shuke, H Bunko… - Journal of Nuclear …, 1993 - europepmc.org
Technetium-99m tetrofosmin is a new myocardial perfusion imaging agent that accumulates
rapidly and shows slow clearance from the myocardium. Dynamic acquisition and SPECT …
rapidly and shows slow clearance from the myocardium. Dynamic acquisition and SPECT …
Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease
G Munch, J Neverve, I Matsunari… - The Journal of …, 1997 - search.proquest.com
Subjects and Patients with Coronary Artery Disease Page 1 Myocardial Technetium-99m-Tetrofosmin
and Technetium-99m-Sestamibi Kinetics in Normal Subjects and Patients with Coronary Artery …
and Technetium-99m-Sestamibi Kinetics in Normal Subjects and Patients with Coronary Artery …
The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime.
DS Berman, H Kiat, J Maddahi - Circulation, 1991 - europepmc.org
The two new 99m (99mTc) labeled myocardial perfusion agents, 99mTc-Sestamibi and
99mTc-Teboroxime, are now available for routine clinical application. Both agents allow …
99mTc-Teboroxime, are now available for routine clinical application. Both agents allow …
Related searches
- 99m tetrofosmin myocardial imaging
- technetium 99m artery disease
- technetium 99m perfusion imaging
- technetium 99m direct comparison
- artery disease myocardial imaging
- pharmacologic interventions myocardial imaging
- technetium 99m photon emission
- 99m tetrofosmin normal subjects
- noninvasive detection myocardial imaging
- technetium 99m dynamic analysis
- coronary angiography tomographic imaging
- myocardial tomography 99mtc tetrofosmin
- technetium 99m myocardial imaging
- 99m tetrofosmin artery disease
- technetium 99m normal subjects