[PDF][PDF] A simple filtering routine for radionuclide bone images

PGB Ross, PF Sharp, PE Undrill - Journal of nuclear medicine, 1985 - Soc Nuclear Med
RESULTS Each responsecan be classifiedas either a correct or incor rect identification of an
abnormality, ie, true-or false-posi tive response, respectively. These are shown in Tables …

[PDF][PDF] Comparison of quantitative and visual detection of new focal bone lesions

WR Pitt, PF Sharp - Journal of nuclear medicine, 1985 - Soc Nuclear Med
Visual assessment of single images Before quantitative analysis can be applied to an
image, lesion contrast must be high enough for an ob server to suspect that an area is …

Optimizing the performance and interpretation of bone scans

LR MUROFF - Clinical Nuclear Medicine, 1981 - journals.lww.com
P" scANNING continues to enjoy the exponential growth that was initiated with the
introduction of the technetium-labeled, phosphorus-containing bone scanning agents …

[BOOK][B] Orthopedic nuclear medicine

AH Elgazzar, AH Elgazzar - 2004 - Springer
It has been several years since the nuclear medicine community was presented with an
outstanding text on bone scintigraphy. Over a span of three decades the value of this …

Clinical use of radionuclide bone imaging in a university medical center

SD Fihn, EB Larson, TR Rudd, WB Nelp - JAMA, 1982 - jamanetwork.com
To assess the diagnostic utility of radionuclide bone imaging, we reviewed all examinations
performed during a two-year period in a university medical center. The indication (s) for each …

Factors influencing bone scan quality

FG Adams, AW Shirley - European journal of nuclear medicine, 1983 - Springer
A reliable subjective method of assessing bone scan quality is described. A large number of
variables which theoretically could influence scan quality were submitted to regression and …

[PDF][PDF] A practical compromise in bone scanning

P Braunstein, JG Hernberg… - Journal of Nuclear …, 1971 - Soc Nuclear Med
FIG. 2. Eighteen-year-oldmanwithprovenHodgkin'sdisease and pain referable to
positivearea. †Dynapix― scan (A) showsposi information density of 30— 40counts/cm2 …

[PDF][PDF] Rectilinear transmission scanning of irregular bones for quantification of mineral content

JM Vogel, JT Anderson - Journal of nuclear medicine, 1972 - Soc Nuclear Med
Data calculation utilizes the formula illustrated in Fig 5. Each row is calculated separately.
The aver ag@ counting rate at each side of the bone (through tissue and water only) …

Bone scanning of trauma and benign conditions

P Matin - Nuclear medicine annual 1982, 1982 - inis.iaea.org
[en] This chapter focuses on selected benign skeletal disorders, especially injuries, and
begins with a discussion of the parameters that can be used to help differentiate benign from …

Interpretation of bone scans

DE Butler, M Brucer - JAMA, 1974 - jamanetwork.com
An informal survey of nonacademic nuclear medicine laboratories indicates that about three
fourths do bone scans; most do only a few, but some do more than 50 a month …
In response to a complaint we received under the US Digital Millennium Copyright Act, we have removed 1 result(s) from this page. If you wish, you may read the DMCA complaint that caused the removal(s) at LumenDatabase.org.