[CITATION][C] Role of technetium-99m phosphonate bone and indium-111 leukocyte scanning for detecting the infected hip prosthesis
PJ Mountford, AJ Coakley - Journal of Nuclear Medicine, 1989 - Soc Nuclear Med
In our study,[@ Tc] MDP bone scans were classified into the followingdistributionsof
radioactivityaround the pros thesis: normal uptake, focally abnormal uptake, diffusely ab …
radioactivityaround the pros thesis: normal uptake, focally abnormal uptake, diffusely ab …
99Tcm-MDP, 67Ga-citrate and 111In-leucocytes for detecting prosthetic hip infection
PJ Mountford, FM Hall, CP Wells… - Nuclear Medicine …, 1986 - journals.lww.com
An assessment was made of the roles of 99 Tc m-MDP, 67 Ga-citrate and 111 In-leucocytes
in identifying infected hip prostheses. Fifty painful prosthetic hips were investigated with a 99 …
in identifying infected hip prostheses. Fifty painful prosthetic hips were investigated with a 99 …
A false-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis
N FELDMAN, PT MAKLER JR… - Clinical nuclear medicine, 1986 - journals.lww.com
A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote
prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with …
prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with …
[PDF][PDF] Sequential technetium-99m HMDP-gallium-67 citrate imaging for the evaluation of infection in the painful prosthesis
KD Merkel, ML Brown… - Journal of nuclear …, 1986 - Soc Nuclear Med
MATERIALS AND METHODS We retrospectively reviewed the charts of all patients who had
sequential Tc— Ga images performed from September 1975 to December 1981. One …
sequential Tc— Ga images performed from September 1975 to December 1981. One …
Diagnosis and management of the infected hip prosthesis
RH Fitzgerald - Orthopedics, 1995 - journals.healio.com
Patients who experience painful total hip arthroplasty (THA) must be presumed to be
infected until proven otherwise. One of the major difficulties is differentiating diagnostically …
infected until proven otherwise. One of the major difficulties is differentiating diagnostically …
99Tcm-diphosphonate scanning as an aid to diagnosis of infection in total hip joint replacements
ED Williams, RJ Tregonning… - The British Journal of …, 1977 - academic.oup.com
Local infection following total hip joint replacement is often difficult to diagnose. Bone
scanning with 99Tcm-diphosphonate has been used in an attempt to detect such infection …
scanning with 99Tcm-diphosphonate has been used in an attempt to detect such infection …
Antigranulocyte scintigraphy in infected hip prosthesis: the diagnostic importance of delayed 20–24-h imaging and semiquantitative analysis
D Rubello, L Rampin, E Banti, G Grassetto… - Nuclear Medicine …, 2008 - journals.lww.com
Aim To evaluate clinical efficacy of a dual-time acquisition protocol, which included 4 and
20/24-h imaging with antigranulocyte antibody scintigraphy (LeukoScan) combined with …
20/24-h imaging with antigranulocyte antibody scintigraphy (LeukoScan) combined with …
[PDF][PDF] Indium-111 chloride imaging in the detection of infected prostheses
BA Sayle, HD Fawcett, DJ Wilkey… - Journal of nuclear …, 1985 - Soc Nuclear Med
MATERIALS AND METHODS Thirty-three adult patients with painful joint pros theses 2 to 9
yr following surgery were referred to help determine if the cause of the pain was loosening …
yr following surgery were referred to help determine if the cause of the pain was loosening …
[CITATION][C] Diagnosing prosthetic joint infection
NP Alazraki - Journal of Nuclear Medicine, 1990 - Soc Nuclear Med
Forreprintscontact: NaomiAlazrakl, MD, do Director, Divisionof Nuclear Medicine, Emory
Lk@ iversityHospital. 1364 CliftonRoad, NE, At larna, GA30322. bone scans, gallium, indium …
Lk@ iversityHospital. 1364 CliftonRoad, NE, At larna, GA30322. bone scans, gallium, indium …
99Tcm-polyclonal IgG scintigraphy in the detection of infected hip and knee prostheses
MO Demirkol, I Adalet, SN Ünal, R Tözün… - Nuclear medicine …, 1997 - journals.lww.com
We investigated the usefulness of 99 Tc m-polyclonal human IgG (99 Tc m-HIG) scintigraphy
in the diagnosis of infected hip and knee prostheses. Twenty-nine scintigraphic studies were …
in the diagnosis of infected hip and knee prostheses. Twenty-nine scintigraphic studies were …
Related searches
- leukocyte scanning hip prosthesis
- leukocyte scanning technetium 99m
- hip prosthesis technetium 99m
- hip prosthesis antigranulocyte scintigraphy
- hip prosthesis semiquantitative analysis
- hip prosthesis diagnostic importance
- evaluation of infection technetium 99m
- citrate imaging technetium 99m
- painful prosthesis technetium 99m
- hip prosthesis diagnosis and management