PH Murphy, JA Burdine, M Calderon - Journal of Nuclear …, 1974 - Soc Nuclear Med
DISCUSSION For a fixed-diameter NaI (Tl) crystal, the useful field of view of a system with a
converging colli mator will decrease as the magnification increases. Because of this field-of …

[PDF][PDF] Method for reducing the energy dependence of the resolution of focused collimators

DJ Wyper, FC Gillespie, I Hall - Journal of Nuclear Medicine, 1972 - Soc Nuclear Med
METHOD FOR REDUCING THE ENERGY DEPENDENCE OF THE RESOLUTION OF
FOCUSED COLLIMATORS Page 1 Where the septa of focused collimators are thick enough to …

[PDF][PDF] A variable angle slant-hole collimator

RH Moore, NM Alpert, HW Strauss - Journal of Nuclear Medicine, 1983 - Soc Nuclear Med
A Variable Angle Slant-Hole Collimator Page 1 A Variable Angle Slant-Hole Collimator
Richard H. Moore, Nathaniel M. Alpert, and H. William Strauss Massachusetts General …

Converging collimation and a large-field-of-view scintillation camera.

PH Murphy, JA Burdine, RA Moyer - Journal of Nuclear Medicine …, 1975 - europepmc.org
Three low-energy multihole converging collimators were evaluated in reference to accepted
imaging parameters using a prototype large-field-of-view scintillation camera. A substantial …

Evaluation of Focused Collimator Performance III. Three- and Five-Inch-Diameter Collimators For 131I and 99mTc

GJ Hine, SP Tsialas - … Radioisotope Scintigraphy. VI Proceedings of a …, 1969 - inis.iaea.org
[en] Focused collimators for radioisotope scanning must be chosen according to their spatial
resolution as a function of source-to-collimator distance, their plane-source sensitivity, and …

Distortion in converging collimator scintiphotography

PH Murphy, JA Burdlne - Radiology, 1977 - pubs.rsna.org
Distortion is intrinsic to converging collimator scintiphotography although converging
collimation offers improved resolution and sensitivity. The nature of the distortion is defined …

A “depth-independent” collimator for use with 99mTc in both conventional and transverse section scanning

AV Lakshmanan, DA Causer, RJ Wilks… - International Journal of …, 1975 - Elsevier
The design of a “depth independent” collimator for use with 99m Tc is discussed. Since this
is a novel design, not available commercially, experimental measurements of line spread …

Magnification in pediatric nuclear medicine

RT Davis, RE Zimmerman, ST Treves - Pediatric nuclear medicine, 1995 - Springer
Magnification is an indispensable technique in pediatric nuclear medicine that is used to
improve the relatively low resolution characteristics of gamma cameras typically equipped …

[CITATION][C] Use of the magnifying or converging collimator in brain scanning

PA Bardfeld, S Rudin - Journal of Nuclear Medicine, 1973 - Soc Nuclear Med
Higher resolution in brain scanning is achieved by the use of magnifying or converging
collimators compared with the resolution obtainable using standard parallel-hole …

[BOOK][B] Image ability of collimators in nuclear medicine: supplementary collimator date for rectilinear scanners

JC Ehrhardt, LW Oberley, JM Cuevas - 1978 - books.google.com
This Supplement covers rectilinear scanner collimators only, and contains the complete line
spread function (LSF) and modulation transfer function (MTF) data synopsized in Table 2 of …