[PDF][PDF] Myocardial uptake and kinetic properties of technetium-99m-Q3 in dogs

MC Gerson, RW Millard, AJ McGoron… - Journal of Nuclear …, 1994 - Soc Nuclear Med
99rnTcactMty &) was related to myocard@ I blood flow (x) from 0 to 6.1 mI/min/gby the
relationshipy= 0.83 X+ 0.18, r= 0.95, p= 0.0001. The ScmntigraphiCra@ oof …

[PDF][PDF] Myocardial clearance kinetics of technetium-99m-SQ30217: a marker of regional myocardial blood flow

RE Stewart, M Schwaiger, GD Hutchins… - Journal of Nuclear …, 1990 - Soc Nuclear Med
METHODS Open-Chested Heart Preparation Ten mongrel dogs of both sexes weighing
12— 25kg were anesthetized with iv pentobarbital (30 mg/kg). Each dog was intubated and …

Kinetic properties of 99mTc-Q12 in canine myocardium.

MC Gerson, RW Millard, NJ Roszell, AJ McGoron… - Circulation, 1994 - Am Heart Assoc
BACKGROUND 99mTc-Q12 is a new Tc (III) perfusion imaging agent that permits prompt
myocardial visualization in humans. We postulated that 99mTc-Q12 myocardial activity is …

Technetium 99m—Q12 kinetics in perfused rat myocardium: Effects of hypoxia and low flow

RD Okada, KN Nguyen, M Lauinger, IL Allton… - American Heart …, 1996 - Elsevier
Technetium 99m—Q12 is a new cationic myocardial perfusion imaging agent that produces
excellent images in human beings. The purpose of this study was to examine the separate …

Myocardial Kinetics of 99mTechnetium-Q Agents: Studies in Isolated Cardiac Myocyte, Isolated Perfused Rat Heart, and Canine Regional Myocardial Ischemia …

AJ McGORON, D BINIAKIEWICZ… - Investigative …, 1999 - journals.lww.com
Abstract McGoron AJ, Biniakiewicz D, Millard RW, et al. Myocardial kinetics of 99m
Technetium-Q agents: Studies in isolated cardiac myocyte, isolated perfused rat heart, and …

Effects of no flow and reperfusion on technetium-99m-Q12 kinetics.

RD Okada, KN Nguyen, M Lauinger… - Journal of Nuclear …, 1995 - europepmc.org
Methods In six control buffer perfused rat hearts, flow was maintained at 12 ml/min
throughout uptake and clearance. In six hearts (IR30), 30 min of no flow was followed by 60 …

Comparison of imaging properties of technetium 99m Q12 and technetium 99m Q3 in humans

MC Gerson, J Lukes, E Deutsch, D Biniakiewicz… - Journal of Nuclear …, 1995 - Springer
Background This study was a direct comparison of the imaging characteristics of 99m Tc-
labeled Q12 (99m Tc-Q12) and 99m Tc-labeled Q3 (99m Tc-Q3) in the same patients …

Clearance of technetium 99m N-NOET in normal, ischemic-reperfused, and membrane-disrupted myocardium

G Johnson III, IL Allton, KN Nguyen, JM Lauinger… - Journal of Nuclear …, 1996 - Elsevier
Background. Technetium 99m-labeled bis (N-ethoxy, N-ethyl dithiocarbamato) nitrido
technetium (v)(99mTcN-NOET) is a new neutral cardiac perfusion imaging agent that has …

[PDF][PDF] Effects of ouabain on technetium-99m-Q12 and thallium-201 extraction and retention by isolated rat heart

AJ McGoron, MC Gerson, DS Biniakiewicz… - Journal of Nuclear …, 1996 - Soc Nuclear Med
The mechanisms of myocardial extraction and retention of the new cationic lipophilic
radionuclide imaging agent 99rrTc-Q12 are cur rently unknown. We hypothesized that"" Tc …

Experimental studies of the physiologic properties of technetium-99m agents: myocardial transport of perfusion imaging agents

DJ Meerdink, JA Leppo - The American journal of cardiology, 1990 - Elsevier
The physiologic properties of new technetium-99m-labeled myocardial imaging agents (Tc-
99m sestamibi, an isonitrile; and Tc-99m teboroxime, a boronic acid adduct of technetium …