[PDF][PDF] Anatomic validation of spatial normalization methods for PET
SPGR 0.938 x 0.938 x 0.934 physical characteristics and general acquisition parameters of
the PET and MRI scanners used in each center. Data analyses were performed with all 24 …
the PET and MRI scanners used in each center. Data analyses were performed with all 24 …
Validation of anatomical standardization of FDG PET images of normal brain: comparison of SPM and NEUROSTAT
Purpose Statistical parametric mapping (SPM) and NEUROSTAT (NS) are widely used for
intersubject statistical analysis of brain images. We investigated individual anatomical …
intersubject statistical analysis of brain images. We investigated individual anatomical …
Anatomical localization for PET using MR imaging
CC Meltzer, RN Bryan, HH Holcomb… - Journal of computer …, 1990 - journals.lww.com
Accurate localization of an imaging plane of interest is often needed prior to a positron
emission tomographic (PET) study. We have developed a simple method for accurate and …
emission tomographic (PET) study. We have developed a simple method for accurate and …
[HTML][HTML] A computed tomography-based spatial normalization for the analysis of [18F] fluorodeoxyglucose positron emission tomography of the brain
H Cho, JS Kim, JY Choi, YH Ryu… - Korean journal of …, 2014 - ncbi.nlm.nih.gov
Objective We developed a new computed tomography (CT)-based spatial normalization
method and CT template to demonstrate its usefulness in spatial normalization of positron …
method and CT template to demonstrate its usefulness in spatial normalization of positron …
Clinical validation of fully 3-D versus 2.5-D RAMLA reconstruction on the Philips-ADAC CPET PET scanner
S Chiang, C Cardi, S Matej, H Zhuang… - Nuclear medicine …, 2004 - journals.lww.com
Materials and methods Ninety patient scans acquired on the Philips CPET scanner at our
institution were reconstructed using 2.5-D RAMLA and 3-D RAMLA with differing …
institution were reconstructed using 2.5-D RAMLA and 3-D RAMLA with differing …
Measuring PET spatial resolution using a cylinder phantom positioned at an oblique angle
A cylinder phantom positioned at a slightly oblique angle with respect to the z-axis of a PET
scanner allows for fine sampling of the edge-spread function. We show how this technique …
scanner allows for fine sampling of the edge-spread function. We show how this technique …
A practical, automated quality assurance method for measuring spatial resolution in PET
The use of different scanners, acquisition protocols, and reconstruction algorithms has been
identified as a problem that limits the use of PET in multicenter trials. The aim of this project …
identified as a problem that limits the use of PET in multicenter trials. The aim of this project …
The effect of patient positioning aids on PET quantification in PET/MR imaging
F Mantlik, M Hofmann, MK Werner, A Sauter… - European journal of …, 2011 - Springer
Abstract Objectives Clinical PET/MR requires the use of patient positioning aids to
immobilize and support patients for the duration of the combined examination. Ancillary …
immobilize and support patients for the duration of the combined examination. Ancillary …
PET/CT today and tomorrow
DW Townsend, JPJ Carney, JT Yap… - Journal of Nuclear …, 2004 - Soc Nuclear Med
Accurate anatomic localization of functional abnormalities seen with PET is known to be
problematic. Even though nonspecific tracers such as 18 F-FDG visualize certain normal …
problematic. Even though nonspecific tracers such as 18 F-FDG visualize certain normal …
Quantitative comparison of spatial normalization algorithms for 3D PET brain scans
J Piper - 2007 - Soc Nuclear Med
1694 Objectives: Statistical comparison of functional brain volumes often requires an
alignment step of each brain volume into a common template space to ensure that …
alignment step of each brain volume into a common template space to ensure that …