Impact of myocardial perfusion imaging with PET and 82Rb on downstream invasive procedure utilization, costs, and outcomes in coronary disease management
ME Merhige, WJ Breen, V Shelton… - Journal of Nuclear …, 2007 - Soc Nuclear Med
We hypothesized that PET myocardial perfusion imaging with 82Rb (PET MPI), would
reduce downstream utilization of diagnostic arteriography, compared with SPECT, in …
reduce downstream utilization of diagnostic arteriography, compared with SPECT, in …
The study of myocardial perfusion and coronary anatomy imaging roles in CAD (SPARC): design, rationale, and baseline patient characteristics of a prospective …
R Hachamovitch, JR Johnson, MA Hlatky… - Journal of Nuclear …, 2009 - Elsevier
Objectives To design a multicenter study comparing the prognostic value and post-test
resource utilization of PET, CT Coronary Angiography (CTA), and SPECT in clinical practice …
resource utilization of PET, CT Coronary Angiography (CTA), and SPECT in clinical practice …
Does quantification of myocardial flow reserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease?
MC Ziadi, RA Dekemp, K Williams, A Guo… - Journal of Nuclear …, 2012 - Springer
Background Relative myocardial perfusion imaging (MPI) is the standard imaging approach
for the diagnosis and prognostic work-up of coronary artery disease (CAD). However, this …
for the diagnosis and prognostic work-up of coronary artery disease (CAD). However, this …
82Rb PET myocardial perfusion imaging is superior to 99mTc-labelled agent SPECT in patients with known or suspected coronary artery disease
Purpose We compared the quality, interpretive confidence and interreader agreement
between SPECT and PET myocardial perfusion imaging (MPI) in the same group of patients …
between SPECT and PET myocardial perfusion imaging (MPI) in the same group of patients …
Combined quantitative assessment of myocardial perfusion and coronary artery calcium score by hybrid 82Rb PET/CT improves detection of coronary artery disease
Hybrid PET myocardial perfusion imaging (MPI) with CT allows the incorporation of coronary
artery calcium (CAC) into the clinical protocol. We aimed to determine whether the combined …
artery calcium (CAC) into the clinical protocol. We aimed to determine whether the combined …
Clinical decision making with myocardial perfusion imaging in patients with known or suspected coronary artery disease
P Cremer, R Hachamovitch, B Tamarappoo - Seminars in nuclear medicine, 2014 - Elsevier
Myocardial perfusion imaging (MPI) to diagnose coronary artery disease (CAD) is best
performed in patients with intermediate pretest likelihood of disease; unfortunately, pretest …
performed in patients with intermediate pretest likelihood of disease; unfortunately, pretest …
Automated quantitative Rb-82 3D PET/CT myocardial perfusion imaging: normal limits and correlation with invasive coronary angiography
R Nakazato, DS Berman, D Dey, L Le Meunier… - Journal of Nuclear …, 2012 - Elsevier
Background We aimed to characterize normal limits and to determine the diagnostic
accuracy for an automated quantification of 3D 82-Rubidium (Rb-82) PET/CT myocardial …
accuracy for an automated quantification of 3D 82-Rubidium (Rb-82) PET/CT myocardial …
[HTML][HTML] Clinical quantification of myocardial blood flow using PET: joint position paper of the SNMMI cardiovascular council and the ASNC
VL Murthy, TM Bateman, RS Beanlands, DS Berman… - 2018 - Springer
Radionuclide myocardial perfusion imaging (MPI) is among the most commonly performed
diagnostic tests in cardiology. Although the diagnostic and prognostic applications of …
diagnostic tests in cardiology. Although the diagnostic and prognostic applications of …
Regional, artery-specific thresholds of quantitative myocardial perfusion by PET associated with reduced myocardial infarction and death after revascularization in …
KL Gould, NP Johnson, AE Roby… - Journal of Nuclear …, 2019 - Soc Nuclear Med
Because randomized coronary revascularization trials in stable coronary artery disease
(CAD) have shown no reduced myocardial infarction (MI) or mortality, the threshold of …
(CAD) have shown no reduced myocardial infarction (MI) or mortality, the threshold of …
Rationale and design of the REgistry of Fast Myocardial Perfusion Imaging with NExt generation SPECT (REFINE SPECT)
Background We aim to establish a multicenter registry collecting clinical, imaging, and follow-
up data for patients who undergo myocardial perfusion imaging (MPI) with the latest …
up data for patients who undergo myocardial perfusion imaging (MPI) with the latest …
Related searches
- perfusion imaging disease management
- perfusion imaging procedure utilization
- disease management procedure utilization
- artery disease myocardial perfusion
- perfusion imaging normal limits
- perfusion imaging decision making
- artery disease flow reserve
- artery disease h215o pet
- artery disease hybrid imaging
- artery disease coronary angiography
- hybrid imaging h215o pet
- coronary angiography h215o pet
- coronary angiography hybrid imaging
- perfusion imaging artery disease