[CITATION][C] Localization of Radiolabeled Streptavidin in Tumor—Reply
M Zhang, Z Yao, H Sakahara… - Journal of Nuclear …, 1998 - Soc Nuclear Med
TO THE EDITOR: In a January 1998 article Zhang et al.(I) compared the biodistribution of
radiolabeled biotin administered to mice bearing a human colon xenograft with that of …
radiolabeled biotin administered to mice bearing a human colon xenograft with that of …
Localization of radiolabeled streptavidin in tumor/Reply
RA Fawwaz, TST Wang, M Zhang… - The Journal of Nuclear …, 1998 - search.proquest.com
TO THE EDITOR: In a January 1998 article Zhang et al.(1) compared the biodistribution of
radiolabeled biotin administered to mice bearing a human colon xenograft with that of …
radiolabeled biotin administered to mice bearing a human colon xenograft with that of …
Localization of Radiolabeled Streptavidin in Tumor
E Ohtake - Soc Nuclear Med
TO THE EDITOR: In a January 1998 article Zhang et al.(I) compared the biodistribution of
radiolabeled biotin administered to mice bearing a human colon xenograft with that of …
radiolabeled biotin administered to mice bearing a human colon xenograft with that of …
Thein vivouses of streptavidin and biotin: a short progress report
DJ Hnatowich - Nuclear Medicine Communications, 1994 - journals.lww.com
unintended effect of free avidin administered after the conjugated antibody and before the
labelled biotin. Recent studies have shown that both tumour [13] and infection/inflammation …
labelled biotin. Recent studies have shown that both tumour [13] and infection/inflammation …
[PDF][PDF] Imaging of tumor in patients with indium-111-labeled biotin and streptavidin-conjugated antibodies: preliminary communication
HP Kalofonos, M Rusckowski… - Journal of Nuclear …, 1990 - Soc Nuclear Med
This report describes preliminary results in a limited clinical trial of the pretargeting concept
in patients in which streptavidin and biotin have been employed be cause of the high affinity …
in patients in which streptavidin and biotin have been employed be cause of the high affinity …
Improved tumor localization with (strept) avidin and labeled biotin as a substitute for antibody
DJ Hnatowich, B Fritz, F Virzi, G Mardirossian… - Nuclear Medicine and …, 1993 - Elsevier
Because of its short physical half life, the use of anti-tumor antibodies radiolabeled with 99m
Tc has necessitated early (ie 2–6 h post-administration) imaging. It is possible that at these …
Tc has necessitated early (ie 2–6 h post-administration) imaging. It is possible that at these …
[CITATION][C] Streptavidin and biotin as potential tumor imaging agents
P Oehr, J Westermann, HJ Biersack - Journal of Nuclear Medicine, 1988 - Soc Nuclear Med
Whole-body images of nude rats bearing HeLa cell tumors on their left hind leg and injected
iv with (1251) streptavidin. Images obtained 1 hr and 48 hr after injectionof the radi olabeled …
iv with (1251) streptavidin. Images obtained 1 hr and 48 hr after injectionof the radi olabeled …
Intravenous avidin chase improved localization of radiolabeled streptavidin in intraperitoneal xenograft pretargeted with biotinylated antibody
M Zhang, H Sakahara, Z Yao, T Saga… - Nuclear medicine and …, 1997 - Elsevier
In the present study, we examined the effect of avidin administered intravenously (iv) on the
biodistribution of radiolabeled streptavidin in mice bearing intraperitoneal (IP) xenografts …
biodistribution of radiolabeled streptavidin in mice bearing intraperitoneal (IP) xenografts …
Effect of endogenous biotin on the applications of streptavidin and biotin in mice
M Rusckowski, M Fogarasi, B Fritz… - Nuclear medicine and …, 1997 - Elsevier
The use of streptavidin-conjugated antibody to pretarget tumors in animals and patients,
prior to administration of radiolabeled biotin, has provided encouraging results, in part …
prior to administration of radiolabeled biotin, has provided encouraging results, in part …
Correlation of tumor radiation-absorbed dose with response is easier to find in previously untreated patients
KF Koral, MS Kaminski, RL Wahl - Journal of Nuclear Medicine, 2003 - Soc Nuclear Med
TO THE EDITOR: I would like to comment on the recent article by Tsopelas and Sutton (1)
regarding the identification of dyes that may be useful in visual identification of the sentinel …
regarding the identification of dyes that may be useful in visual identification of the sentinel …