Krypton-81m imaging of the right ventricle

M Horn, K Witztum, C Neveu, G Perkins… - Journal of nuclear …, 1985 - Soc Nuclear Med
We report the development of a method for obtaining right-ventricular radionuclide
angiograms using continuous peripheral intravenous infusion of the ultra-short-lived nuclide …

Assessment of right ventricular function and anatomy using peripheral vein infusion of krypton 81m

DD Sugrue, S Kamal, JE Deanfield… - The British Journal of …, 1983 - birpublications.org
A method for imaging the right side of the heart (atrium, ventricle and main pulmonary artery)
and for assessment of RV systolic function (ejection fraction and ejection rate) is described …

[PDF][PDF] Gated right ventricular studies using krypton-81m: comparison with first-pass studies using gold-195m

JL Caplin, WD Flatman, DS Dymond - Journal of nuclear …, 1986 - Soc Nuclear Med
JVec ecognition of the importance of right ventricular function (/) has led to the interest in
methods for its noninvasivc assessment (2). Because of the right ventri cle's complex …

Definition of myocardial perfusion by continuous infusion of krypton-81m

E Kaplan, LW Mayron, AM Friedman, JE Gindler… - The American Journal of …, 1976 - Elsevier
Krypton-81m, a radionuclide emitting a 190 kev gamma ray, has a half-life of 13 seconds. It
is a radioisotope of an inert water-soluble noble gas and is produced at a constant rate by …

Clinical use of ultrashort-lived radionuclide krypton-81m for noninvasive analysis of right ventricular performance in normal subjects and patients with right ventricular …

CA Nienaber, RP Spielmann, G Wasmus… - Journal of the American …, 1985 - Elsevier
The ultrashort-lived radionuclide krypton-Sim, eluted in 5% dextrose from a bedside
rubidium-81m generator, was intravenously infused for rapid imaging of the right-sided heart …

The evaluation of right ventricular performance using krypton-81m

HR Ham, A Piepsz, J Vandevivere… - Clinical nuclear …, 1983 - journals.lww.com
The availability of krypton-81 m suitable for intravenous injection provides an easy means
for assessing right ventricular function. The superimposition of the other heart chambers …

[PDF][PDF] Radiopotassium-38 for in vivo studies of dynamic processes

WG Myers - Journal of Nuclear Medicine, 1973 - Soc Nuclear Med
MYERS to achieve directionality by means of the two back to-back ±y-rays of 38K, which
are emitted 180 deg to each other, should make this instrument at least ten times more …

Production and use of 81Rb-sup(81m)Kr for clinical tissue perfusion measurements with the Anger camera

PV Harper, B Rich, KA Lathrop, B Mock - Dynamic studies with …, 1975 - inis.iaea.org
[en] The measurement of tissue perfusion using the ratio of sup (81m) Kr to 81 Rb is based
on the fact that rubidium is rapidly distributed in the intracellular space, while krypton is a …

[PDF][PDF] Gated xenon scans for right ventricular function

W Martin, AC Tweddel, I McGhie… - Journal of nuclear …, 1986 - Soc Nuclear Med
The complex geometry of the right ventricle makes the use of radionuclides an attractive
method for assessing right ventricular function. The use of the gated 133Xetechnique for this …

Continuous assessment of regional myocardial perfusion in dogs using krypton-81m.

AP Selwyn, T Jones, H Turner, T Pratt, J Clark… - Circulation …, 1978 - Am Heart Assoc
Krjplon-81m has been continuously eluted in 5% dextrose from a cyclotron-made rubidium-
81 generator. The unique physical properties of this inert freely diffusible gas (half-life 13 …