Planar imaging versus gated blood-pool SPECT for the assessment of ventricular performance: a multicenter study
MW Groch, EG DePuey, AC Belzberg… - Journal of Nuclear …, 2001 - Soc Nuclear Med
Gated blood-pool SPECT (GBPS), inherently 3-dimensional (3D), has the potential to
replace planar equilibrium radionuclide angiography (ERNA) for computation of left …
replace planar equilibrium radionuclide angiography (ERNA) for computation of left …
Left ventricular ejection fraction and volumes from gated blood-pool SPECT: comparison with planar gated blood-pool imaging and assessment of repeatability in …
GA Wright, S Thackray, S Howey… - Journal of Nuclear …, 2003 - Soc Nuclear Med
Gated blood-pool SPECT (GBPS) has several potential advantages over planar
radionuclide ventriculography (PRNV), including the possibility of greater repeatability of left …
radionuclide ventriculography (PRNV), including the possibility of greater repeatability of left …
Model dependence of gated blood pool SPECT ventricular function measurements
K Nichols, N Humayun, PD Bondt… - Journal of nuclear …, 2004 - Springer
Background Calculation differences between various gated blood pool (GBP) single photon
emission computed tomography (SPECT)(GBPS) algorithms may arise as a result of …
emission computed tomography (SPECT)(GBPS) algorithms may arise as a result of …
Planar radionuclide angiography with a dedicated cardiac SPECT camera
Background We compared a dedicated cardiac camera with a traditional system for left
ventricular (LV) functional measurements using gated blood-pool imaging. Methods 24 …
ventricular (LV) functional measurements using gated blood-pool imaging. Methods 24 …
Electrocardiographically gated blood-pool SPECT and left ventricular function: comparative value of 3 methods for ejection fraction and volume estimation
D Daou, F Harel, BO Helal, T Fourme… - Journal of Nuclear …, 2001 - Soc Nuclear Med
The current major limitation to development of electrocardiographically (ECG) gated blood-
pool SPECT (GBPS) for measurement of the left ventricular (LV) ejection fraction (LVEF) and …
pool SPECT (GBPS) for measurement of the left ventricular (LV) ejection fraction (LVEF) and …
Gated blood-pool SPECT automated versus manual left ventricular function calculations
RH Slart, L Poot, DA Piers… - Nuclear medicine …, 2004 - journals.lww.com
Planar gated blood-pool imaging (GBPI) is a standard method for non-invasive assessment
of left ventricular (LV) function. Gated blood-pool single photon emission computed …
of left ventricular (LV) function. Gated blood-pool single photon emission computed …
Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT
SJ Kim, IJ Kim, YS Kim, YK Kim - The international journal of …, 2005 - Springer
Gated blood pool SPECT (GBPS) is an alternative to planar radionuclide ventriculography
(PRNV) and offers potential advantages. The aim of this study was to compare 8 and 16 …
(PRNV) and offers potential advantages. The aim of this study was to compare 8 and 16 …
Quantitative gated blood pool SPECT for the assessment of coronary artery disease at rest
MW Groch, RC Marshall, WD Erwin… - Journal of Nuclear …, 1998 - Elsevier
Background. Planar gated blood pool imaging (GBPI) has long proven to be useful for the
noninvasive assessment of ventricular function. From a practical viewpoint, gated blood pool …
noninvasive assessment of ventricular function. From a practical viewpoint, gated blood pool …
Comparative values of gated blood-pool SPECT and CMR for ejection fraction and volume estimation
L Sibille, FB Bouallegue, A Bourdon… - Nuclear medicine …, 2011 - journals.lww.com
Objective Gated blood-pool single-photon emission computed tomography (GBPS) was
compared with cardiac magnetic resonance (CMR) for the measurement of left ventricular …
compared with cardiac magnetic resonance (CMR) for the measurement of left ventricular …
Validation of gated blood-pool SPECT regional left ventricular function measurements
KJ Nichols, A Van Tosh, Y Wang… - Journal of Nuclear …, 2009 - Soc Nuclear Med
Blood-pool (BP)–gated SPECT should be able to detect regional left ventricular (LV)
dysfunction, as the modality is fully 3-dimensional and capable of resolving all cardiac …
dysfunction, as the modality is fully 3-dimensional and capable of resolving all cardiac …
Related searches
- planar imaging blood pool
- ventricular performance blood pool
- planar imaging ventricular performance
- ejection fraction blood pool
- volume estimation blood pool
- assessment of repeatability blood pool
- heart failure blood pool
- volume estimation left ventricular function
- ventricular volumes ejection fraction
- volume estimation ejection fraction
- ventricular volumes blood pool
- repeatability in patients blood pool