Abnormality manipulation of PET images
357 Objectives Image perception studies using clinical PET images can be challenging
because of the difficulty in compiling control and target cases. We have developed and …
because of the difficulty in compiling control and target cases. We have developed and …
Improved implementation of the abnormality manipulation software tools
MT Madsen, KS Berbaum, KM Schartz… - … Imaging 2011: Image …, 2011 - spiedigitallibrary.org
Collecting clinical cases for medical imaging perception studies is often challenging. We
have developed a suite of software tools for manipulating medical tomographic image sets …
have developed a suite of software tools for manipulating medical tomographic image sets …
Reducing inter-scanner PET image variability
168 Objectives: Our goal is to reduce systematic inter-scanner PET image variability. In spite
of standardized protocols for scanner calibration, normalization, attenuation/scatter/randoms …
of standardized protocols for scanner calibration, normalization, attenuation/scatter/randoms …
A more clinically relevant assessment of PET spatial resolution.
M Zimmer, S Leonard, M Gruchot, G Dillehay - 2021 - Soc Nuclear Med
175 Objectives: Spatial resolution testing of PET scanners, per the National Electric
Manufacturers Association (NEMA) protocol, is performed using a very specific method. A 1 …
Manufacturers Association (NEMA) protocol, is performed using a very specific method. A 1 …
Selecting a new PET/CT system
MT Madsen - Journal of the American College of Radiology, 2004 - Elsevier
Conclusion The selection, purchase, and installation of a PET/CT system is a major
undertaking. It is important to involve site planners early in the process for proper room …
undertaking. It is important to involve site planners early in the process for proper room …
Rapid automated algorithm for aligning and reslicing PET images
RP Woods, SR Cherry, JC Mazziotta - Journal of computer …, 1992 - journals.lww.com
A computer algorithm for the three-dimensional (3D) alignment of PET images is described.
To align two images, the algorithm calculates the ratio of one image to the other on a voxel …
To align two images, the algorithm calculates the ratio of one image to the other on a voxel …
Introduction to PET instrumentation
TG Turkington - Journal of nuclear medicine technology, 2001 - Soc Nuclear Med
Objective: The purpose of this paper is to introduce technologists to the basic principles of
PET imaging and to the instrumentation used to acquire PET data. PET imaging is currently …
PET imaging and to the instrumentation used to acquire PET data. PET imaging is currently …
PET/CT image navigation and communication
O Ratib - Journal of Nuclear Medicine, 2004 - Soc Nuclear Med
The advent of multimodality imaging scanners combining PET and CT has led to a new
paradigm in image display and presentation that raises new challenges in workstation …
paradigm in image display and presentation that raises new challenges in workstation …
" Deep Dive Into PET-CT": Developing an Efficient and Effective Search Pattern In Interpreting PET-CT For Nuclear Physicians and Residents.
M Boulos, J Kim, E Gofur, M Rubin, J Meshekow… - 2023 - Soc Nuclear Med
P132 Introduction:-Learn how visual search patterns can be categorized and described.-
Examine how subspecialists conduct searches through abdominopelvic CTs, and what …
Examine how subspecialists conduct searches through abdominopelvic CTs, and what …
Comparison of performance between board-certified physicians and medically naive readers in a simple PET images detection task
P183 Introduction: Image reconstruction remains an active area of investigation for PET
imaging and other tomographic imaging modalities. Reconstruction algorithms balance data …
imaging and other tomographic imaging modalities. Reconstruction algorithms balance data …