Characterization of 68Ga-DOTA-D-Phe1-Tyr3-octreotide kinetics in patients with meningiomas

M Henze, A Dimitrakopoulou-Strauss… - Journal of Nuclear …, 2005 - Soc Nuclear Med
Because biopsy has a high risk of hemorrhage and the findings of CT and MRI are often
ambiguous, especially at the base of the skull, additional methods for the characterization of …

PET imaging of somatostatin receptors using [68GA] DOTA-D-Phe1-Tyr3-octreotide: first results in patients with meningiomas

M Henze, J Schuhmacher, P Hipp… - Journal of Nuclear …, 2001 - Soc Nuclear Med
Imaging of somatostatin receptors (SSTRs) using [111In] diethylenetriaminepentaacetic-acid-
octreotide (DTPAOC) has proven to be helpful in the differentiation of meningiomas …

[HTML][HTML] 68Ga-DOTATATE PET-CT as a tool for radiation planning and evaluating treatment responses in the clinical management of meningiomas

ES Kowalski, R Khairnar, AA Gryaznov, V Kesari… - Radiation …, 2021 - Springer
Background and purpose Meningiomas express the somatostatin receptor (SSTR), which
normal bone and brain lack. PET imaging with SSTR ligands such as 68 Ga-DOTATATE …

Detection of cranial meningiomas: comparison of 68Ga-DOTATOC PET/CT and contrast-enhanced MRI

A Afshar-Oromieh, FL Giesel, HG Linhart… - European journal of …, 2012 - Springer
Purpose PET imaging with somatostatin receptor ligands, such as 68 Ga-DOTATOC, is a
well-established method for detection and target volume definition of meningiomas prior to …

[HTML][HTML] Meningiomas: A Comparative Study of 68Ga-DOTATOC, 68Ga-DOTANOC and 68Ga-DOTATATE for Molecular Imaging in Mice

ML Soto-Montenegro, S Pena-Zalbidea… - PLoS …, 2014 - journals.plos.org
Purpose The goal of this study was to compare the tumor uptake kinetics and diagnostic
value of three 68Ga-DOTA-labeled somatostatin analogues (68Ga-DOTATOC, 68Ga …

[HTML][HTML] The Role of [68Ga]Ga-DOTA-SSTR PET Radiotracers in Brain Tumors: A Systematic Review of the Literature and Ongoing Clinical Trials

P Palmisciano, G Watanabe, A Conching… - Cancers, 2022 - mdpi.com
Simple Summary [68Ga] Ga-DOTA-SSTR PET imaging has recently been introduced in the
management of patients with brain tumors, mostly meningiomas and pituitary adenomas or …

PET SUV correlates with radionuclide uptake in peptide receptor therapy in meningioma

H Hänscheid, RA Sweeney, M Flentje, AK Buck… - European journal of …, 2012 - Springer
Purpose To investigate whether the tumour uptake of radionuclide in peptide receptor
radionuclide therapy (PRRT) of meningioma can be predicted by a PET scan with 68 Ga …

Comparative biodistribution and radiation dosimetry of 68Ga-DOTATOC and 68Ga-DOTATATE in patients with neuroendocrine tumors

M Sandström, I Velikyan… - Journal of Nuclear …, 2013 - Soc Nuclear Med
68Ga-DOTATOC and 68Ga-DOTATATE are 2 radiolabeled somatostatin analogs for in vivo
diagnosis of neuroendocrine tumors with PET. The aim of the present work was to measure …

Potential impact of 68Ga-DOTATOC PET/CT on stereotactic radiotherapy planning of meningiomas

F Nyuyki, M Plotkin, R Graf, R Michel, I Steffen… - European journal of …, 2010 - Springer
Purpose Since meningiomas show a high expression of somatostatin receptor subtype 2,
PET with 68 Ga-DOTATOC was proposed as an additional imaging modality beside CT and …

Increased 68Ga-DOTATATE uptake in PET imaging discriminates meningioma and tumor-free tissue

W Rachinger, VM Stoecklein, NA Terpolilli… - Journal of Nuclear …, 2015 - Soc Nuclear Med
Meningiomas are known to express somatostatin receptor 2 (SSTR2). PET using the SSTR2
analog 68Ga-DOTATATE has recently been introduced for imaging of meningiomas …