[PDF][PDF] Evaluation of infections of the locomotor system with indium-111-labeled human IgG scintigraphy

MW Nijhof, WJG Oyen, A van Kampen… - Journal of Nuclear …, 1997 - Soc Nuclear Med
RESULTS The overall infection prevalence was 27%(62 foci). Staph-ylococcus species
were cultured from 17 foci (38%), Strepto coccus species from 13 foci (29%), Pseudomonas …

[PDF][PDF] The efficacy of indium-111-polyclonal IgG for the detection of infection and inflammation

FL Datz, CE Anderson, R Ahluwalia… - Journal of Nuclear …, 1994 - Soc Nuclear Med
I 1@ IgO study; biopsy, surgery, additional nuclear medicinescansand
radiOgraphICstudieswereusedto confirm the lgG scan results. Resufts: The polydonal lgG …

[PDF][PDF] Infectious imaging with indium-111-labeled nonspecific polyclonal human immunoglobulin

WA Wegener, MG Velchik, D Weiss, S Ter… - Journal of Nuclear …, 1991 - Soc Nuclear Med
Infectious Imaging with Indium-.111-Labeled Nonspecific Polyclonal Human
Immunoglobulin Page 1 tivity and specificity for the detection of abdominal infec tion. Indium-l …

Diagnosis of bone, joint, and joint prosthesis infections with In-111-labeled nonspecific human immunoglobulin G scintigraphy.

WJ Oyen, JR van Horn, RA Claessens, TJ Slooff… - Radiology, 1992 - pubs.rsna.org
The diagnostic accuracy of scintigraphy performed after injection of indium-111-labeled
nonspecific human immunoglobulin G (IgG) was studied in 113 patients with 120 foci of …

[PDF][PDF] Comparison of purified indium-111 granulocytes and indium-111 mixed leukocytes for imaging of infections

DS Schauwecker, RW Burt, HM Park… - Journal of nuclear …, 1988 - Soc Nuclear Med
RESULTS Table 2 contains the number of patients with true positive results in acute
osteomyelitis (AOM), chronic osteomyelitis (COM), acute soft-tissue infection (AST) and …

Clinical evaluation of a scintigraphic method for diagnosing inflammations/infections using indium-111-labeled nonspecific human IgG.

AN Serafini, I Garty, R Vargas-Cuba… - Journal of Nuclear …, 1991 - europepmc.org
This study was undertaken as part of a Phase II study to assess the sensitivity and safety of
111In-DTPA-human IgG, an imaging agent for the detection of inflammations and/or …

[PDF][PDF] Effect of antibiotic therapy on the sensitivity of indium-111-labeled leukocyte scans

FL Datz, DA Thorne - Journal of nuclear medicine, 1986 - Soc Nuclear Med
MATERIALS AND METHODS Three hundred twelve leukocyte scans on 271 pa tients (some
patients underwent several exams) were retrospectively reviewed. The scans were …

The efficacy of technetium-99m ciprofloxacin (Infecton) imaging in suspected orthopaedic infection: a comparison with sequential bone/gallium imaging

Z Yapar, M Kibar, FA Yapar, E Toğrul… - European journal of …, 2001 - Springer
Technetium-99m ciprofloxacin (Infecton) has recently become established as a new
radiopharmaceutical for the imaging of infection. This study was performed to determine the …

[PDF][PDF] Scintigraphic detection of bone and joint infections with indium-111-labeled nonspecific polyclonal human immunoglobulin G

WJG Oyen, R Claessens, JR van Horn… - J Nucl …, 1990 - Soc Nuclear Med
99mTcMDP skeletal scintigraphy had been completed, or after the second-phaseimages of
99mTcMDpscintigraphywere obtained. The latter procedure was followed when operation …

[PDF][PDF] Indium-111-granulocyte scintigraphy in brain abscess diagnosis: limitations and pitfalls

KG Schmidt, JW Rasmussen… - Journal of Nuclear …, 1990 - Soc Nuclear Med
RESULTS Table 1 summarizes our results. The final diagnosis was brain abscess in 8
patients, brain tumor or metas tasis in 18 patients, and infarct and hematoma in 1 patient …