[PDF][PDF] Reply No. 1

ME Phelps, EJ Hoffman - Journal of Nuclear Medicine, 1976 - Soc Nuclear Med
Two recent publications (1, 2) in the Journal of Nuclear Medicine have discussed the loss of
spatial resolution in positron imaging devices due to the varying range of posi trons of …

[PDF][PDF] Resolution Limit for Positron-Imaging Devices—Reply

EJ Hoffman, ME Phelps - Journal of Nuclear Medicine, 1977 - Soc Nuclear Med
Three letters in Vol. 17 of this Journal have discussed the effects of positron range and
annihilation-angle spread (ie deviations from 180Â) on the resolution limit of posi tron …

[PDF][PDF] Positron camera with extended counting rate capability

G Muehllehner - Journal of Nuclear Medicine, 1975 - Soc Nuclear Med
MUEHLLEHNER energy band as Compton events. Figure 1, Curve B shows the energy
spectrum of a point source sur rounded by Scattering material, the difference be tween …

Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution

CS Levin, EJ Hoffman - Physics in Medicine & Biology, 1999 - iopscience.iop.org
Developments in positron emission tomography (PET) technology have resulted in systems
with finer detector elements designed to further improve spatial resolution. However, there is …

[PDF][PDF] Positron ranges obtained from biomedically important positron-emitting radionuclides

ZH Cho, JK Chan, L Ericksson, M Singh… - Journal of nuclear …, 1975 - Soc Nuclear Med
In recent times there has been renewed interest in scintigraphic imaging of positron emitters,
particu larly in connection with three-dimensional tomogra phy using positron annihilation …

Positron camera with longitudinal and transverse tomographic capabilities

G Muehllehner, F Atkins, PV Harper - Medical radionuclide imaging, 1977 - inis.iaea.org
[en] The capability to reconstruct both longitudinal or transverse tomographic slices with the
positron camera system affords unique advantages. The longitudinal tomographic mode …

[PDF][PDF] Comments on specifying the performance of a positron tomograph

EJ Hoffman - Journal of Nuclear Medicine, 1982 - Soc Nuclear Med
(FWHM) ofthe count profile (line-spread function) through the reconstructed image ofa line
source (1). Several variables (often unspecified) can affect the FWHM. First, as the diameter …

[PDF][PDF] I. BASIC POSITRON EMISSION TOMOGRAPHY PRINCIPLES

T LEWELLEN, J KARP - bme.unc.edu
The goal of positron emission tomography (PET) is to generate images of the distribution of
positron emitters in vivo. PET systems rely on the detection of annihilation gamma rays that …

Historic perspective

MN Croll - Seminars in Nuclear Medicine, 1994 - Elsevier
Recording the chronology of nuclear medicine instrumentation poses some difficult
decisions as does the determination of the “father” of nuclear medicine?. Historians can …

High resolution tomography of positron emitters using highly focused pinhole collimation

F Beekman, F van der Have - 2007 - Soc Nuclear Med
312 Objectives: With SPECT using stationary NaI detectors and highly focussed multi-
pinhole (HFMP) collimators (U-SPECT-I & II) sub-half mm resolution images can be …