[PDF][PDF] A nonimaging scintillation probe to measure penile hemodynamics

LS Zuckier, GR Korupolu, M Gladshteyn… - Journal of Nuclear …, 1995 - Soc Nuclear Med
We have developed a penile nonirnaging scintillation (PNIS) probe consisting of a plastic
well-type scintillation crystal inter faced to a portable computer and acquisitionboard …

Use of radioactive tracers in the evaluation of penile hemodynamics: history, methodology and measurements

LS Zuckier - International journal of impotence research, 1997 - nature.com
Radionuclide tracer techniques are intimately associated with some of the early ground-
breaking investigations in erectile dysfunction and have evolved along with the field. At the …

Penile radionuclide studies in impotence: an overview

QH Siraj, AJW Hilson - Nuclear Medicine Communications, 1993 - journals.lww.com
penile circulatory status. Among the early nonradio-nuclide techniques of evaluating penile
arterial function, penile blood pressure measurements by various methods and Doppler …

The effect of intracavernosal haemodilution on the radionuclide quantification of penile vascular changes during pharmacologically induced penile erections

QH Siraj, J Bomanji, M Ahmed - Nuclear medicine …, 1992 - journals.lww.com
Radionuclide phallography was performed using 99 Tc m-labelled red blood cells in
conjunction with pharmacologically induced penile erections. The radioactivity content of …

Physiological considerations in radionuclide imaging of the penis during impotence therapy.

TK Chaudhuri, S Fink, RH Burger, IC Netto… - American journal of …, 1989 - europepmc.org
The increased use of intracorporeal drugs in the treatment of impotence has advanced our
understanding of erectile physiology. Radionuclide imaging of the penis (nuclear penogram) …

Quantitation of pharmacologically-induced penile erections: the value of radionuclide phallography in the objective evaluation of erectile haemodynamics

QH Siraj, J Bomanji, MA Akhtar, MH Rana… - Nuclear Medicine …, 1990 - journals.lww.com
This study combines the pharmacologically-induced penile erection (PIPE) technique with
radionuclide phallography (RNP) for the non-invasive study of penile haemodynamic …

[PDF][PDF] A dual-radioisotope technique for the evaluation of penile blood flow during tumescence

F Miraldi, AD Nelson, WT Jones… - Journal of Nuclear …, 1992 - Soc Nuclear Med
A technique is described for concomitant study of both arterial and venous penile blood flow
during tumescence. Dual-isotope acquisition is started after labeling red cells in vivo with …

A pilot study of flaccid penile blood flow patterns in normal subjects and patients with erectile dysfunction

QH Siraj, AJW Hilson, J Bomanji… - Nuclear medicine …, 1993 - journals.lww.com
Dynamic penile scintigraphy was performed using 99 Tc m-labelled autologous erythrocytes
in five normally potent volunteers and 22 patients with erectile dysfunction including 11 …

A dynamic dual isotope radionuclear method of quantifying penile blood flow

ED Kursh, WT Jones, S Thompson, D Nelson… - The Journal of …, 1992 - Elsevier
A new radionuclear method of quantifying arterial and venous blood flow of the penis is
described. The technique is based on the simultaneous recording of the change in blood …

[PDF][PDF] Radionuclide assessment of penile corporal venous leak using Technetium-99m-labeled red blood cells

D Groshar, S Lidgi, A Frenkel… - Journal of Nuclear …, 1992 - Soc Nuclear Med
In an attempt to evaluate penile corporal venous outflow, a method that utilizes intracorpora
[injection of Tc-RBC was developed and used in 20 patients with erectile dysfunction. Seven …