[PDF][PDF] Quantitative analysis of radiophosphate uptakes in asymptomatic porous-coated hip endoprostheses
L Rosenthall, ME Ghazal… - Journal of Nuclear …, 1991 - Soc Nuclear Med
We have evidence that different designs of cementless prostheses may have different
normal ratios for a given parameter. In progress is a prospective quantitative assess ment of …
normal ratios for a given parameter. In progress is a prospective quantitative assess ment of …
Three-phase bone scintigraphy pattern of loosening in uncemented hip prostheses
D Rubello, N Borsato, F Chierichetti, P Zanco… - European journal of …, 1995 - Springer
The three-phase bone scintigraphy pattern of loosening in uncemented hip prostheses
(UHPs) has not previously been elucidated. We evaluated 28 patients with complicated …
(UHPs) has not previously been elucidated. We evaluated 28 patients with complicated …
Porous-coated Acetabular Component: Quantitative Assessment of Normal Radiophosphate Uptake as a Function of Implant Age
L ROSENTHALL, LF CHEN, ME GHAZAL… - Clinical Nuclear …, 1991 - journals.lww.com
A computer-assisted quantitative analysis was undertaken of normal radiophosphate bone
uptake adjacent to the porous-coated acetabular component in asymptomatic patients …
uptake adjacent to the porous-coated acetabular component in asymptomatic patients …
[PDF][PDF] Quantitative analysis of technetium-99m-methylene diphosphonate uptake in unilateral hydroxyapatite-coated total hip prostheses: first year of follow-up
AIA Rahmy, AJ Tonino, WD Tan - Journal of Nuclear Medicine, 1994 - Soc Nuclear Med
Methods: Patients were imaged periodicallywhile they were asymptomatic at 1, 3, 6 and 12
mo postoperatively. Quantitative measurements were performed with a region of interest …
mo postoperatively. Quantitative measurements were performed with a region of interest …
Radionuclide bone imaging of femoral prostheses with porous coatings.
M SPECTOR, WB WIGGER… - Clinical Orthopaedics and …, 1981 - journals.lww.com
MATERIALS AND METHODS Six porous polysulfone-coated” cobalt-chromium femoral
prostheses (Fig. 1) were implanted in five dogs (> 25kg). Results of previous studies13 …
prostheses (Fig. 1) were implanted in five dogs (> 25kg). Results of previous studies13 …
Hip and knee prostheses: evaluation of the natural history of periprosthetic bone changes
L Rosenthall - Seminars in nuclear medicine, 1997 - Elsevier
This is a review of normal adaptive bone remodeling in response to hip and knee
endoprostheses as manifested by changes in regional bone mineral density and …
endoprostheses as manifested by changes in regional bone mineral density and …
Uptake of 99mTc-MDP after uncemented hip arthroplasty: a quantitative analysis of findings around the femoral component in asymptomatic patients
RN Maniar, RC Todd, S Robinson… - The Journal of Bone & …, 1997 - boneandjoint.org.uk
We studied the pattern of 99mTc-methylene diphosphonate uptake around uncemented
femoral components in 44 asymptomatic hip arthroplasties, performing isotope scans at …
femoral components in 44 asymptomatic hip arthroplasties, performing isotope scans at …
[PDF][PDF] Three-phase bone scan and indium white blood cell scintigraphy following porous coated hip arthroplasty: a prospective study of the prosthetic tip
SG Oswald, D Van Nostrand, CG Savory… - Journal of nuclear …, 1989 - Soc Nuclear Med
Three-PhaseBone Scan and Indium White Coated Hip Arthroplasty: A Prospective Study Page
1 though the complications of prosthetic loosening and infection are uncommon following total …
1 though the complications of prosthetic loosening and infection are uncommon following total …
Observations on para-articular uptake of radiophosphate after hip replacement
L Rosenthall, C Rush - European journal of nuclear medicine, 1986 - Springer
A correlation was made between the incidence and intensity of 99m Tc-methylene
diphosphonate (MDP) concentration and the rediographic incidence and volume of …
diphosphonate (MDP) concentration and the rediographic incidence and volume of …
Natural progress of a bone scan after cementless hydroxyapatite-coated total hip arthroplasty
KT Suh, CB Lee, IJ Kim - Clinical Orthopaedics and Related …, 2001 - journals.lww.com
To establish the natural progress pattern of postoperative bone uptake, a periprosthetic
quantitative technetium-99m methylene diphosphonate scintiscan was done on 80 …
quantitative technetium-99m methylene diphosphonate scintiscan was done on 80 …
Related searches
- quantitative analysis hip endoprostheses
- quantitative analysis asymptomatic patients
- quantitative analysis femoral component
- quantitative assessment radiophosphate uptake
- quantitative analysis diphosphonate uptake
- acetabular component radiophosphate uptake
- quantitative analysis 99m methylene
- femoral component asymptomatic patients
- quantitative analysis 99mtc mdp
- hip arthroplasty asymptomatic patients
- 99mtc mdp asymptomatic patients
- femoral component hip arthroplasty
- femoral component 99mtc mdp
- hip prostheses diphosphonate uptake
- quantitative analysis hip prostheses
- quantitative analysis hip arthroplasty