Performance of a Monolithic Crystal PET Detector with Integrated Retroreflectors

L Saleh, P Vaska - 2022 - Soc Nuclear Med
3314 Introduction: The standard commercial positron emission tomography (PET) detector
uses pixelated scintillation crystals that provide an average spatial resolution of 4-5 mm. The …

Compton PET: a layered structure PET detector with high performance

P Peng, MS Judenhofer, SR Cherry - Physics in Medicine & …, 2019 - iopscience.iop.org
In most high-resolution PET detector designs, there is an inherent trade-off between spatial
resolution and detector efficiency. We have developed and tested a new geometry for the …

High-resolution monolithic detector design for clinical Positron emission tomography systems

M Stockhoff, R Van Holen… - 17th National Day on …, 2018 - biblio.ugent.be
INTRODUCTION State-of-the-art clinical positron emission tomography (PET) scanners
utilize detector blocks consisting of many pixelated scintillation crystals. First systems in the …

Performance study of a large monolithic LYSO PET detector with accurate photon DOI using retroreflector layers

A Gonzalez-Montoro, A Aguilar… - … on Radiation and …, 2017 - ieeexplore.ieee.org
Clinical and organ-dedicated PET systems typically require a high efficiency imposing the
use of thick scintillators, normally through crystal arrays. To provide depth of interaction …

Evolution of PET detectors and event positioning algorithms using monolithic scintillation crystals

A Gonzalez-Montoro, AJ Gonzalez… - … on Radiation and …, 2021 - ieeexplore.ieee.org
The use of monolithic scintillator-based photon detectors in positron emission tomography
(PET) has emerged as an attractive alternative to traditional pixelated array designs …

Development of Integrated Corner Retroreflectors for Monolithic PET Detector

L Saleh, T Cotroneo, P Vaska - 2023 IEEE Nuclear Science …, 2023 - ieeexplore.ieee.org
We propose to improve spatial resolution, light collection, and depth of interaction
capabilities of monolithic PET detectors by using corner reflectors machined directly into the …

Monolithic scintillator detectors for high-resolution positron emission tomography

MC Maas - 2008 - repository.tudelft.nl
Positron emission tomography (PET) is a technique for imaging the 3-dimensional
distribution of radio-labelled molecules in vivo. This technique plays an increasingly …

A finely segmented semi‐monolithic detector tailored for high‐resolution PET

Y Kuhl, F Mueller, S Naunheim, M Bovelett… - Medical …, 2024 - Wiley Online Library
Background Preclinical research and organ‐dedicated applications use and require high
(spatial‐) resolution positron emission tomography (PET) detectors to visualize small …

Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction

MC Maas, DR Schaart, DJJ van der Laan… - Physics in Medicine …, 2009 - iopscience.iop.org
We developed positron emission tomography (PET) detectors based on monolithic
scintillation crystals and position-sensitive light sensors. Intrinsic depth-of-interaction (DOI) …

Optical Monte-Carlo simulation to evaluate monolithic PET detector concepts

J Grahe, F Müller, D Schug, P Hallen… - 2017 IEEE Nuclear …, 2017 - ieeexplore.ieee.org
We present a framework based on Geant4 to evaluate the performance ofdifferent monolithic
positron emission tomography (PET) detector stacksetups based on a LYSO: Ce crystal with …