Long-distance transmission of digital scintillation camera signals.
LW Santon, FS Prato, N Aspin - Journal of Nuclear Medicine …, 1976 - europepmc.org
A system is described for the long-distance transmission of digital positional information from
a scintillation camera to a computer through a shielded multiple-twisted-pair cable. Data …
a scintillation camera to a computer through a shielded multiple-twisted-pair cable. Data …
An interface between several cameras and two computers, using differential analog transmission.
FS Prato, E Gauci, TD Cradduck - Journal of Nuclear Medicine …, 1982 - europepmc.org
A system has been built to allow up to four scintillation cameras to be connected in parallel
with two computers, yet provide for selection of individual pairs of camera/computer …
with two computers, yet provide for selection of individual pairs of camera/computer …
[PDF][PDF] An improved data recorder for scintillation cameras
RD Bliss, PM Weber… - Journal of Nuclear …, 1974 - Soc Nuclear Med
FIG. 1. Blockdiagramof analogrecordersystem. Signal. processing functions are shown only
for x coordinate channel. y co. ordinates of image dots are processedin identical fashion and …
for x coordinate channel. y co. ordinates of image dots are processedin identical fashion and …
A new method of assessing the performance of scintillation cameras and scanners
TD Cradduck, SO Fedoruk… - Physics in Medicine & …, 1966 - iopscience.iop.org
Methods are described to make possible the comparisons of spatial resolution, sensitivity
and distortion for stationary and moving detector scanners. The spatial resolution is …
and distortion for stationary and moving detector scanners. The spatial resolution is …
[CITATION][C] Digital and Analog Processing of Anger Camera Data with a Dedicated Computer—Controlled System
WL Ashburn, KM Moser, M Guisan - Journal of Nuclear Medicine, 1970 - Soc Nuclear Med
METHOD The operation of the Anger scintillation camera is well known (12). In the system
discussed in this report, the camera is unaffected by the operation of the additional …
discussed in this report, the camera is unaffected by the operation of the additional …
A digital computer data acquisition, display, and analysis system for the gamma camera
FP Bruno, VA Brookeman, CM Williams - Radiology, 1970 - pubs.rsna.org
A digital computer data acquisition, display, and analysis system for use with a scintillation
camera is described. The system makes possible quantitative analysis of a scan image now …
camera is described. The system makes possible quantitative analysis of a scan image now …
[PDF][PDF] A large-area, high-resolution scintillation camera based on delay-line time conversion
E Tanaka, N Nohara, N Kumano… - Medical radioisotope …, 1973 - inis.iaea.org
Abstract A LARGE-AREA, HIGH-RESOLUTION SCINTILLATION CAMERA BASED ON
DELAY-LINE TIME CONVERSION. A new scintillation camera utilizing a 387-mm-diameter …
DELAY-LINE TIME CONVERSION. A new scintillation camera utilizing a 387-mm-diameter …
Signal processing in scintillation cameras for nuclear medicine
FPMH Jansen, DM Binnie - US Patent 5,504,334, 1996 - Google Patents
It is an object of the invention to reduce the above described problems of noise. The present
invention is based on the realization that there are two different types of noise encountered …
invention is based on the realization that there are two different types of noise encountered …
An experimental determination of the overall spatial resolution of a scintillation camera
TD Cradduck, SO Fedoruk - Physics in Medicine & Biology, 1965 - iopscience.iop.org
An experimental method is described to assess the spatial resolution of the crystal, light pipe
and photomultipliers of a scintillation camera. This resolution may then be related to the …
and photomultipliers of a scintillation camera. This resolution may then be related to the …
[PDF][PDF] A data acquisition and processing system for rapid dynamic investigations with a scintillation camera
F Bitter, WE Adam - Medical radioisotope scintigraphy 1972, 1973 - inis.iaea.org
Until recently, data processing in nuclear medicine was understood to mean the use ofa
computer in scintigraphy with the aim of improving the image quality [1-8]. The spatial …
computer in scintigraphy with the aim of improving the image quality [1-8]. The spatial …