Validations for MR-based partial volume correction for brain PET imaging

K Matsubara, M Ibaraki, T Maeda, T Kinoshita - 2016 - Soc Nuclear Med
1930 Objectives Several methods to correct partial volume effect (PVE), based on magnetic
resonance (MR) images, have been proposed and utilized widely in PET studies. However …

Objective evaluation of voxelwise partial volume correction methods in brain PET imaging

M Bilgel, Y Zhu, O Rousset, D Wong, S Resnick… - 2020 - Soc Nuclear Med
72 Introduction: Partial volume effects impair the accurate quantification of PET scans, and
are important consideration in voxelwise statistical analyses. A number of methods have …

Partial volume correction strategies for parametric images

P Zanotti-Fregonara, CT Li, C Comtat, S Zoghbi… - 2013 - Soc Nuclear Med
2041 Objectives Partial volume correction (PVC) is necessary in brain PET studies to
differentiate an artefactual reduction in radiotracer uptake due to cerebral atrophy from a true …

MRI-guided partial volume correction in brain PET imaging: comparison of five algorithms

G Boivin, V Genoud, H Zaidi - Frontiers in Biomedical Technologies, 2014 - fbt.tums.ac.ir
Purpose: Positron Emission Tomography (PET) imaging offers the possibility of measuring
brain metabolic activity in vivo. However, brain PET images remain difficult to interpret in …

Quantitative assessment by means of realistic simulated images and patient data of a new method for partial volume correction in brain PET

N Boussion, CC Le Rest, Y Bizais, D Visvikis - 2006 - Soc Nuclear Med
550 Objectives: The partial volume effects (PVE) in cerebral FDG PET have two main
outcomes. Firstly, they lead to imprecision when calculating mean activity in regions of …

[HTML][HTML] Brain partial volume correction with point spreading function reconstruction in high-resolution digital PET: comparison with an MR-based method in FDG …

M Ibaraki, K Matsubara, Y Shinohara… - Annals of Nuclear …, 2022 - Springer
Objective In quantitative positron emission tomography (PET) of the brain, partial volume
effect due mainly to the finite spatial resolution of the PET scanner (> 3 mm full width at half …

MRI-guided voxel-based partial volume effect correction in brain PET: assessment of the impact of 3 MR image segmentation algorithms

ML Montandon, F Assal, O Ratib, H Zaidi - NeuroImage, 2009 - Elsevier
Methods The accuracy of anatomically-guided PVC algorithms in brain PET is largely
dependent on the performance of segmentation algorithms (Zaidi et al., 2006) partitioning …

A Deep Learning model for Partial Volume Correction without Using Prior Knowledge Information

A Sanaat, H Shooli, A Boehringer, M Sadeghi, I Shiri… - 2022 - Soc Nuclear Med
3225 Introduction: The partial volume effect (PVE) is a consequence of the limited spatial
resolution of PET scanners. PVE causes the underestimation of intensity values of a …

No-gold-standard evaluation of partial volume compensation methods for brain PET

Y Zhu, Z Liu, M Bilgel, A Rahmim, A Jha - 2021 - Soc Nuclear Med
1409 Objectives: Partial volume effects (PVE) are known to degrade quantitative accuracy in
PET, and thus multiple partial volume compensation (PVC) methods have been developed …

Anatomically guided voxel-based partial volume effect correction in brain PET: impact of MRI segmentation

D Gutierrez, ML Montandon, F Assal, M Allaoua… - … Medical Imaging and …, 2012 - Elsevier
Partial volume effect is still considered one of the main limitations in brain PET imaging
given the limited spatial resolution of current generation PET scanners. The accuracy of …