SIMIND Monte Carlo validation for Lutetium-177 imaging

K Ramonaheng - 2019 - Soc Nuclear Med
1349 Objectives: Due to the development of new peptides Lu-177 has gained popularity as
one of the isotopes of choice for peptide receptor radionuclide therapy using the …

[HTML][HTML] Energy window and collimator optimization in lutetium-177 single-photon emission computed tomography imaging using Monte Carlo simulation

H Asmi, F Bentayeb, Y Bouzekraoui… - Indian Journal of …, 2020 - journals.lww.com
Materials and Methods: Siemens Medical System Symbia fitted with high-energy (HE),
medium-energy (ME), and low-energy high-resolution collimators was simulated using the …

[PDF][PDF] Validation of a SIMIND Monte Carlo modelled gamma camera for Iodine-123 and Iodine-131 imaging

M Morphis, JA van Staden, H du Raan, M Ljungberg - Heliyon, 2021 - cell.com
Abstract Purpose Monte Carlo (MC) modelling techniques can assess the quantitative
accuracy of both planar and SPECT Nuclear Medicine images. It is essential to validate the …

Validation of a Monte Carlo modelled gamma camera for Lutetium-177 imaging

K Ramonaheng, JA van Staden, H du Raan - Applied Radiation and …, 2020 - Elsevier
This study validated a model of the Siemens Symbia T16 dual-head SPECT/CT gamma
camera created using the Monte Carlo program SIMIND for 177 Lu. The validation was done …

[HTML][HTML] Validation of Tc and Lu quantification parameters for a Monte Carlo modelled gamma camera

G Di Domenico, S Di Biaso, L Longo, A Turra, E Tonini… - EJNMMI physics, 2023 - Springer
Abstract Purpose Monte Carlo (MC) simulation in Nuclear Medicine is a powerful tool for
modeling many physical phenomena which are difficult to track or measure directly. MC …

Gamma camera calibration and validation for quantitative SPECT imaging with 177Lu

M D'Arienzo, M Cazzato, ML Cozzella, M Cox… - Applied Radiation and …, 2016 - Elsevier
Over the last years 177 Lu has received considerable attention from the clinical nuclear
medicine community thanks to its wide range of applications in molecular radiotherapy …

[PDF][PDF] Modelling of energy-dependent spectral resolution for SPECT Monte Carlo simulations using SIMIND

M Morphis, JA van Staden, H du Raan, M Ljungberg - Heliyon, 2021 - cell.com
Abstract Purpose Monte Carlo (MC) modelling techniques have been used extensively in
Nuclear Medicine (NM). The theoretical energy resolution relationship (∝ 1/E), does not …

Validation of SIMIND Monte Carlo for 99mTc and 177Lu

G Di Domenico, S Di Biaso, L Longo, A Turra, E Tonini… - 2022 - researchsquare.com
Purpose: Monte Carlo (MC) simulation in Nuclear Medicine is a powerful tool for modelling
many physical phenomena which are difficult to track or to measure directly. MC simulation …

[HTML][HTML] Towards accurate 177Lu SPECT activity quantification and standardization using lesion-to-background voxel ratio

S Raskin, D Gamliel, D Abookasis, S Ben-Haim… - EJNMMI physics, 2023 - Springer
Background Conventional calibration of the gamma camera consists of the calculation of
calibration factors (CFs)(ratio of counts/cc and true concentration activity) as the function of …

SIMIND Monte Carlo based image reconstruction

M Ljungberg - 2015 - Soc Nuclear Med
43 Objectives In an iterative reconstruction algorithm, a model of the image system is
needed to be able to calculate SPECTprojections. This part of the algorithm is called the …