[PDF][PDF] Sensitivity of technetium-99m-d, l-HMPAO to radiolysis in aqueous solutions

K Tubergen, M Corlija, WA Volkert… - Journal of Nuclear …, 1991 - Soc Nuclear Med
MATERIALSAND METHODS Technetium-99m-d, 1-HMPAO was prepared from a com
mercial kit (Ceretece, Amersham Intl., Arlington Heights, IL) containing 0.5 mg of d, l-4, 8 …

[CITATION][C] Preparation of technetium-99m-HMPAO

J Ballinger - Journal of Nuclear Medicine, 1990 - Soc Nuclear Med
Four HMPAO kits were each reconstituted with 5 ml nitrogen-purgedsterilewaterin a
laminarairflowhood. Ali quots of 1 ml each were transferred into 20 evacuated multi dose …

[PDF][PDF] Kinetic analysis of technetium-99m d, 1-HM-PAO decomposition in aqueous media

JC Hung, M Corlija, WA Volkert… - Journal of nuclear …, 1988 - Soc Nuclear Med
Kinetic Analysis of Technetium-99m d,1-HM-PAO Decomposition in Aqueous Media Page 1
echnetium-99m-d, 1-hexamethylpropyleneamine oxime ([99mTc]d,1HMpAO)is a neutral-lipophilicche …

Stabilisation of high-activity99mTc-d,I-HMPAO preparations with cobalt chloride and their biological behaviour

KO Mang'Era, HP Vanbilloen, CW Schiepers… - European journal of …, 1995 - Springer
It has been reported that the stability of a 1.11-GBq (30 mCi) technetium-99m d, l-
hexamethylpropylene amine oxime (HMPAO) preparation can be improved to up to 5 h by …

Alternative formulations of technetium-99m HMPAO

JR Ballinger, KY Gulenchyn - … and instrumentation. Part A. Applied radiation …, 1991 - Elsevier
Technetium-99m HMPAO is inconvenient to use because of its limited shelf-life after
reconstitution. In an attempt to find a more stable formulation, alternative methods to …

Evaluation of the stability of 99mTc-ECD and stabilized 99mTc-HMPAO stored in syringes

IL Koslowsky, SE Brake, SJ Bitner - Journal of nuclear medicine …, 2001 - Soc Nuclear Med
Objective: To determine and compare the stability of 99mTc-ECD and stabilized 99mTc-
HMPAO when stored in syringes over an 8-h period. Methods: 99mTc-ECD and stabilized …

Studies on some aspects of the instability of Tc-hexamethylpropylene amineoxime (Tc-HMPAO)

N Ramamoorthy, MRA Pillai, DE Troutner - Nuclear Medicine and Biology, 1993 - Elsevier
Abstract Technetium-d, l-hexamethylpropyleneamineoxime (99g Tc-d, l-HMPAO) was
prepared using the long-lived 99g TcO 4− at 5× 10− 7–5× 10− 8 M concentrations and …

Stabilization of technetium-99m—d, l-hexamethylpropyleneamine oxime (99mTc—d, l-HMPAO) using gentisic acid

JC Hung, WA Volkert, RA Holmes - … . Part B. Nuclear Medicine and Biology, 1989 - Elsevier
Abstract Technetium-99m-d, l-hexamethylpropyleneamineoxime (99m Tc-d, l-HMPAO) is a
neutral, lipophilic chelate formed from a kit (Ceretec TM; Amersham International plc, UK) by …

A comparison of three methods to determine the radiochemical purity of 99Tcm-hexamethylpropylene amine oxime (99Tcm-HMPAO)

G Mah, RM Reilly, GLM Wong… - Nuclear Medicine …, 1989 - journals.lww.com
Determining the radiochemical purity of 99 Tc m-HMPAO using the standard method
suggested by the manufacturer of the HMPAO kit is slow, consuming much of the 30 min …

[PDF][PDF] Comparison of technetium-99m MAG3 kit with HPLC-purified technetium-99m MAG3 and OIH in rats

JR Coveney, MS Robbins - Journal of nuclear medicine, 1987 - Soc Nuclear Med
Materials and Methods General Technetium-99m MAO3 was prepared from lyophilized kits
containing 1 mg benzoylMAG3, 40 mg sodium tartrate dihydrate, 20 mg lactose …