Use of wavelet transforms in analysis of time–activity data from cardiac PET
JW Lin, AF Laine, O Akinboboye… - Journal of Nuclear …, 2001 - Soc Nuclear Med
Because of its intrinsic quantitative properties, PET permits measurement of myocardial
perfusion and metabolism in absolute terms (ie, mL/g/min). However, quantification has …
perfusion and metabolism in absolute terms (ie, mL/g/min). However, quantification has …
Quantification of myocardial perfusion in human subjects using 82Rb and wavelet-based noise reduction
JW Lin, RR Sciacca, RL Chou, AF Laine… - Journal of Nuclear …, 2001 - Soc Nuclear Med
Quantification of myocardial perfusion with 82Rb has been difficult to achieve because of the
low signal-to-noise ratio of the dynamic data curves. This study evaluated the accuracy of …
low signal-to-noise ratio of the dynamic data curves. This study evaluated the accuracy of …
Quantification of regional myocardial blood flow using dynamic H215O PET and factor analysis
Because the use of factor analysis has been proposed for extracting pure physiologic
temporal or spatial information from dynamic nuclear medicine images, factor analysis …
temporal or spatial information from dynamic nuclear medicine images, factor analysis …
PET kinetic analysis: wavelet denoising of dynamic PET data with application to parametric imaging
M Shidahara, Y Ikoma, J Kershaw, Y Kimura… - Annals of nuclear …, 2007 - Springer
Physiological functions (eg, cerebral blood flow, glucose metabolism, and neuroreceptor
binding) can be investigated as parameters estimated by kinetic modeling using dynamic …
binding) can be investigated as parameters estimated by kinetic modeling using dynamic …
Estimation of the 18F-FDG input function in mice by use of dynamic small-animal PET and minimal blood sample data
GZ Ferl, X Zhang, HM Wu… - Journal of Nuclear …, 2007 - Soc Nuclear Med
Derivation of the plasma time–activity curve in murine small-animal PET studies is a
challenging task when tracers that are sequestered by the myocardium are used, because …
challenging task when tracers that are sequestered by the myocardium are used, because …
Absolute quantification of myocardial blood flow with H215O and 3-dimensional PET: an experimental validation
KP Schäfers, TJ Spinks, PG Camici… - Journal of Nuclear …, 2002 - Soc Nuclear Med
The purpose of this study was to assess a 3-dimensional (3D)-only PET scanner (ECAT
EXACT3D) for its use in the absolute quantification of myocardial blood flow (MBF) using …
EXACT3D) for its use in the absolute quantification of myocardial blood flow (MBF) using …
[PDF][PDF] Effects of time discrepancies between input and myocardial time-activity curves on estimates of regional myocardial perfusion with PET
P Herrero, JJ Hartman, MJ Senneff… - Journal of Nuclear …, 1994 - Soc Nuclear Med
Accordingly, the aims of the present study were:(1) to evaluate in human subjects the
magnitude of the time dii ferences between the input function obtained from either the left …
magnitude of the time dii ferences between the input function obtained from either the left …
Sampling requirements for dynamic cardiac PET studies using image-derived input functions.
RR Raylman, JM Caraher… - Journal of nuclear …, 1993 - europepmc.org
The utilization of image-derived input functions is becoming common in quantitative PET
studies of the heart. Consequently, imaging protocols must be designed to sample both …
studies of the heart. Consequently, imaging protocols must be designed to sample both …
Myocardial Blood Flow Quantification Using Positron-Emission Tomography–Analysis and Practice in the Clinical Setting–
K Yoshinaga, Y Tomiyama, E Suzuki, N Tamaki - Circulation Journal, 2013 - jstage.jst.go.jp
1663 MBF Quantification With PET produces high-quality images but sometimes shows a
mild defect in the lateral wall even in normal subjects (Figure 1). 17 Caution should therefore …
mild defect in the lateral wall even in normal subjects (Figure 1). 17 Caution should therefore …
Reproducibility of measurements of regional myocardial blood flow in a model of coronary artery disease: comparison of H215O and 13NH3 PET techniques
P Chareonthaitawee, SD Christenson… - Journal of Nuclear …, 2006 - Soc Nuclear Med
PET absolute myocardial blood flow (MBF) with H215O and 13NH3 are widely used in
clinical and research settings. However, their reproducibility with a 16-myocardial segment …
clinical and research settings. However, their reproducibility with a 16-myocardial segment …