A generalized Renkin-Crone relation for Rb-82 GFADS analysis
2040 Objectives Myocardial blood flow (MBF) estimation by Rb-82 dynamic PET typically
requires the use of a generalized Renkin-Crone (gRC) empirical relation. Compared to …
requires the use of a generalized Renkin-Crone (gRC) empirical relation. Compared to …
Effects of filtering on Rb-82 myocardial blood flow estimates
1659 Objectives The objective of this study was to investigate the effect of filtering on
myocardial blood flow (MBF) estimates from the generalized factor analysis of dynamic …
myocardial blood flow (MBF) estimates from the generalized factor analysis of dynamic …
Quantifying the normal range of myocardial blood flow with 13N-ammonia and 82Rb dynamic PET imaging
J Renaud, M Lortie, R Wassenaar, J DaSilva… - 2006 - Soc Nuclear Med
190 Objectives: Diagnosis of coronary artery disease is facilitated by comparing myocardial
perfusion scans with a database defining the regional lower limit of normal. However normal …
perfusion scans with a database defining the regional lower limit of normal. However normal …
Reproducibility of myocardial blood flow quantitation using PET RB-82 and generalized factor and compartment analyses
1062 Objectives: Absolute quantitation of myocardial blood flow (MBF) using dynamic Rb-82
PET has great potential in the assessment of the extent and severity of ischemia in patients …
PET has great potential in the assessment of the extent and severity of ischemia in patients …
Quantification of myocardial blood flow (MBF) from 82Rb cardiac PET studies: A comparison study of two automatic programs
V Dunet, N Abi Hatem, F El Hakmaoui, G Allenbach… - 2010 - Soc Nuclear Med
1325 Objectives 82Rb Cardiac PET yields myocardial perfusion imaging using fast (<
30min) protocols. Dynamic acquisition provides quantitative MBF and has great potential for …
30min) protocols. Dynamic acquisition provides quantitative MBF and has great potential for …
Generation of parametric images from time-of-flight 82Rb and 15O-water cardiac PET with ICA-derived input functions
M Germino, J Ropchan, T Mulnix, S Najafzadeh… - 2014 - Soc Nuclear Med
46 Objectives The purpose of this study was to quantify myocardial blood flow (MBF) in
human subjects with 82 Rb and 15 O-water PET using input functions (IF) derived from …
human subjects with 82 Rb and 15 O-water PET using input functions (IF) derived from …
Error estimation for dynamic PET myocardial blood flow
J Moody, B Lee, E Ficaro - 2012 - Soc Nuclear Med
323 Objectives Myocardial blood flow (MBF) can be estimated by dynamic PET using
various radiotracers. In several cases (eg, Rb-82, C-11 acetate) an empirical fit to the …
various radiotracers. In several cases (eg, Rb-82, C-11 acetate) an empirical fit to the …
Reproducibility and accuracy of quantitative myocardial blood flow assessment with 82Rb PET: comparison with 13N-ammonia PET
82Rb cardiac PET allows the assessment of myocardial perfusion with a column generator
in clinics that lack a cyclotron. There is evidence that the quantitation of myocardial blood …
in clinics that lack a cyclotron. There is evidence that the quantitation of myocardial blood …
Reproducibility of absolute myocardial blood flow (MBF) quantitation using RB-82 PET
167 Objectives: Absolute MBF quantitation with Rb-82 PET has great potential in the
assessment of the extent and severity of ischemia in patients without known coronary artery …
assessment of the extent and severity of ischemia in patients without known coronary artery …
24. Measurement of GFR using 51Cr-EDTA: a re-evaluation of procedures
MB Hanney, PG Hillel, S Senior, A Pickles… - Nuclear Medicine …, 2002 - journals.lww.com
The IPEM/BNMS audit of GFR measurement prompted a re-evaluation of procedures in
Sheffield. All stages of the process have been assessed in order to maximize accuracy. For …
Sheffield. All stages of the process have been assessed in order to maximize accuracy. For …