[PDF][PDF] Comparison of renal extraction efficiencies for radioactive agents in the normal dog

JG McAfee, ZD Grossman, G Gagne… - Journal of Nuclear …, 1981 - Soc Nuclear Med
MATERIALS AND METHODS Adult male mongrel dogs weighing 17-33 kg were
anesthetized with 30-35 mg/kg of sodium pentobarbital intravenously. Arterial and venous …

[PDF][PDF] Physiological determinants of renal tubular passage times

MH Farmelant, K Bakos… - Journal of Nuclear …, 1969 - Soc Nuclear Med
METHODS Eleven mongrel dogs of both sexes, weighing 10. — 20 kg, were the subjects
for these studies. They were anesthetized with 50 mg/kg sodium pentobarbital in …

[CITATION][C] Radionuclides in renal transplantation

G Hör, HW Pabst, KJ Pfeifer… - Journal of Nuclear …, 1972 - Soc Nuclear Med
METHODS Several radionuclide procedures were chosen for the evaluation of function and
morphological dis orders of the renal transplants. These are summarized in Table 1 …

Radionuclide clearance techniques

ML Cohen - Seminars in nuclear medicine, 1974 - Elsevier
A review of methods used in performing radionuclide renal clearance is presented.
Adequate radionuclide substitutes for inulin and paraaminohippurate (PAH) have made …

Study of the double isotope single-injection method for estimating renal function in purebred Beagle dogs.

TE Powers, JD Powers, RC Garg - 1977 - cabidigitallibrary.org
Renal clearance of radioactive chemicals [125I] sodium iothalamate and [131I] sodium
iodohippurate, following a single intravenous injection, was studied in dogs. Three …

[PDF][PDF] Tc-99m DMSA renal uptake: influence of biochemical and physiologic factors

CA Yee, HB Lee, MD Blaufox - Journal of Nuclear Medicine, 1981 - Soc Nuclear Med
Tc-99m DMSARenalUptake:Influenceof BiochemicalandPhysiologicFactors Page 1 Available
data are inadequate concerning the physi ologic mechanisms of localization of the major …

A simplified method of estimating renal function with iodohippurate I131

MD Blaufox, HGW Frohmuller, JC Campbell… - Journal of Surgical …, 1963 - Elsevier
Simultaneous PAH and single injection iodohippurate I 131 clearances were performed 23
times on 14 dogs. Excretion of the radioactive material was evaluated in two ways:(1) the I …

[PDF][PDF] Radioisotope renogram in kidney transplants

MK Loken, EV Staab, RL Vernier… - Journal of Nuclear …, 1964 - Soc Nuclear Med
Presently the radioactive renogram is being used to follow the clinical course of patients who
have received a renal transplant. Collins et al (1) have recently reported their experience in …

Evaluation of 99mTc-diethylenetriaminepentaacetic acid nuclear imaging for quantitative determination of the glomerular filtration rate of dogs.

DR Krawiec, RR Badertscher 2nd… - American Journal of …, 1986 - europepmc.org
The suitability of 99mTc-diethylenetriaminepentaacetic acid (99mTc-DTPA) as an agent to
assess glomerular filtration rate (GFR) in dogs was evaluated. Glomerular filtration rates of …

Experimental models and evaluation of animal data for renal radiodiagnostic agents

JG McAfee, G Subramanian - Animal models in radiotracer design, 1983 - Springer
After a new gamma-emitting radiodiagnostic agent is synthesized and its chemical structure
defined, serial camera imaging following administration to experimental animals can quickly …