Variation of specific activities of 68Ga-aquibeprin and 68Ga-avebetrin enables selective PET imaging of different expression levels of integrins α5β1 and αvβ3
68Ga-aquibeprin and 68Ga-avebetrin are tracers for selective in vivo mapping of integrins
α5β1 and αvβ3, respectively, by PET. Because both tracers exhibit high affinity to their …
α5β1 and αvβ3, respectively, by PET. Because both tracers exhibit high affinity to their …
Complementary, selective PET imaging of integrin subtypes α5β1 and αvβ3 using 68Ga-aquibeprin and 68Ga-avebetrin
Despite in vivo mapping of integrin αvβ3 expression being thoroughly investigated in recent
years, its clinical value is still not well defined. For imaging of angiogenesis, the integrin …
years, its clinical value is still not well defined. For imaging of angiogenesis, the integrin …
In vivo PET imaging of the cancer integrin αvβ6 using 68Ga-labeled cyclic RGD nonapeptides
Expression of the cellular transmembrane receptor αvβ6 integrin is essentially restricted to
malignant epithelial cells in carcinomas of a broad variety of lineages, whereas it is virtually …
malignant epithelial cells in carcinomas of a broad variety of lineages, whereas it is virtually …
[HTML][HTML] PET/CT imaging of head-and-neck and pancreatic cancer in humans by targeting the “Cancer Integrin” αvβ6 with Ga-68-Trivehexin
NG Quigley, K Steiger, S Hoberück, N Czech… - European Journal of …, 2021 - Springer
Purpose To develop a new probe for the αvβ6-integrin and assess its potential for PET
imaging of carcinomas. Methods Ga-68-Trivehexin was synthesized by trimerization of the …
imaging of carcinomas. Methods Ga-68-Trivehexin was synthesized by trimerization of the …
One-Step 18F Labeling of Non-Peptidic Bivalent Integrin αvβ3 Antagonist for Cancer Imaging
W Wang, Z Liu, Z Li - Bioconjugate chemistry, 2015 - ACS Publications
A rapid one-step 18F labeling reaction with fluoridealuminum complex, which is based on
chelation chemistry, has received a surge of interest for 18F radiolabeling of peptides. In this …
chelation chemistry, has received a surge of interest for 18F radiolabeling of peptides. In this …
68Ga-NODAGA-RGDyK for αvβ3 integrin PET imaging
F Buchegger, D Viertl, S Baechler… - Nuklearmedizin …, 2011 - thieme-connect.com
Aim: To visualize neovasculature and/or tumour integrin α v β 3 we selected the binding
moiety Arg-Gly-Asp-D-Tyr-Lys (RGDyK) coupled to NODAGA for labeling with 68 Ga …
moiety Arg-Gly-Asp-D-Tyr-Lys (RGDyK) coupled to NODAGA for labeling with 68 Ga …
PET-based human dosimetry of the dimeric αvβ3 integrin ligand 68Ga-DOTA-E-[c (RGDfK)] 2, a potential tracer for imaging tumor angiogenesis
V López-Rodríguez, C Galindo-Sarco… - Journal of Nuclear …, 2016 - Soc Nuclear Med
Peptides containing the Arg-Gly-Asp (RGD) sequence have high affinity for αvβ3 integrin
receptors overexpressed in tumor cells. The objective of this research was to determine the …
receptors overexpressed in tumor cells. The objective of this research was to determine the …
In vivo biokinetic and metabolic characterization of the 68Ga-labelled α5β1-selective peptidomimetic FR366
C D'Alessandria, K Pohle, F Rechenmacher… - European journal of …, 2016 - Springer
Purpose Integrins are transmembrane receptors responsible for cell–cell adhesion and cell–
extracellular matrix binding and play an important role in angiogenesis and tumour …
extracellular matrix binding and play an important role in angiogenesis and tumour …
Pegylated Arg-Gly-Asp peptide: 64Cu labeling and PET imaging of brain tumor αvβ3-integrin expression
X Chen, Y Hou, M Tohme, R Park… - Journal of Nuclear …, 2004 - Soc Nuclear Med
The αv-integrins, cell adhesion molecules that are highly expressed on activated endothelial
cells and tumor cells but not on dormant endothelial cells or normal cells, present an …
cells and tumor cells but not on dormant endothelial cells or normal cells, present an …
A novel PET tracer for the imaging of αvβ3 and αvβ5 integrins in experimental breast cancer bone metastases
U Mühlhausen, D Komljenovic… - Contrast media & …, 2011 - Wiley Online Library
The aim of this study was the evaluation of 68Ga‐DOTA‐E‐[c (RGDfK)] 2 as a novel PET
tracer to image αvβ3 and αvβ5 integrins. For this purpose, DOTA‐E‐[c (RGDfK)] 2 was …
tracer to image αvβ3 and αvβ5 integrins. For this purpose, DOTA‐E‐[c (RGDfK)] 2 was …
Related searches
- 68ga aquibeprin integrins α5β1
- 68ga aquibeprin expression levels
- integrins α5β1 expression levels
- 68ga aquibeprin pet imaging
- integrins α5β1 pet imaging
- pet imaging expression levels
- pet imaging brain tumor
- pet imaging gly asp
- pet imaging 64cu labeling
- αvβ3 integrin 64cu labeling
- pet tracer αvβ5 integrins
- αvβ3 integrin brain tumor
- αvβ3 integrin gly asp
- 68ga avebetrin integrins α5β1
- 68ga avebetrin expression levels
- 68ga avebetrin pet imaging