[PDF][PDF] Validation studies of iodine-123-iodoamphetamine as a cerebral blood flow tracer using emission tomography

JH Greenberg, M Kushner, M Rango… - Journal of Nuclear …, 1990 - Soc Nuclear Med
MATERIALSAND METhODS All procedures were approved by the Institutional Review
Board of the Universityof Pennsylvania. Informed consent was obtained from each subject …

Functional mapping of flow and back-diffusion rate of N-isopropyl-p-iodoamphetamine in human brain.

Y Yonekura, S Nishizawa, T Mukai… - Journal of Nuclear …, 1993 - europepmc.org
Iodine-123-labeled N-isopropyl-p-iodoamphetamine (IMP) has been reported to be an
excellent tracer for mapping cerebral blood flow with single-photon emission computed …

Quantitative measurement of regional cerebral blood flow using N-isopropyl-(iodine-123) p-iodoamphetamine and single-photon emission computed tomography.

G Takeshita, H Maeda, K Nakane… - Journal of Nuclear …, 1992 - europepmc.org
We have developed a quantitative method of measuring regional cerebral blood flow (rCBF)
by using N-isopropyl-(iodine-123) p-iodoamphetamine and single-photon emission …

A Multicenter Validation of Regional Cerebral Blood Flow Quantitation Using [123I]Iodoamphetamine and Single Photon Emission Computed Tomography

H Iida, T Akutsu, K Endo, H Fukuda… - Journal of Cerebral …, 1996 - journals.sagepub.com
Recently, two methods have been proposed for regional cerebral blood flow (rCBF)
quantitation using [123I] iodoamphetamine (IMP) and single-photon emission computed …

[PDF][PDF] Rapid calculation of regional cerebral blood flow and distribution volume using iodine-123-iodoamphetamine and dynamic SPECT

H Ito, H Iida, PM Bloomfield, M Murakami… - Journal of Nuclear …, 1995 - Soc Nuclear Med
RESULTS The time taken to calculate one slice functional images by the present technique
was about 3 min when the inte gration interval was 1 sec. This calculation speed is about ten …

Regional quantitative noninvasive assessment of cerebral perfusion and function with N-isopropyl-[123I] p-iodoamphetamine

GK Von Schulthess, E Ketz… - Journal of nuclear …, 1985 - Soc Nuclear Med
Although several reports on the clinical usefulness of N-isopropyl-[123I] p-iodoamphetamine
(IMP) in the diagnosis of cerebral disease have appeared in the literature, quantitative …

Database of normal human cerebral blood flow measured by SPECT: I. Comparison between I-123-IMP, Tc-99m-HMPAO, and Tc-99m-ECD as referred with O-15 …

K Inoue, R Goto, S Kinomura, Y Taki, K Okada… - Annals of nuclear …, 2006 - Springer
Objectives Three accumulative tracers, iodine-123-labeled N-isopropyl-p-iodoamphetamine
(I-123-IMP), technetium-99m-labeled hexamethylpropyleneamineoxime (Tc-99m-HMPAO) …

Quantitative cerebral blood flow measurements using N-isopropyl-(iodine 123) p-iodoamphetamine and single photon emission computed tomography with rotating …

H Matsuda, H Seki, H Sumiya, S Tsuji… - American Journal of …, 1986 - europepmc.org
Sixty regional cerebral blood flow measurements were performed on 4 normal volunteers, 7
epileptics, and 40 cerebrovascular disorders using intravenously injected N-isopropyl-(I …

[PDF][PDF] A comparative study of simple methods to measure regional cerebral blood flow using iodine-123-IMP SPECT

M Ohkubo, I Odano, M Takahashi - Journal of Nuclear Medicine, 1997 - Soc Nuclear Med
The aim of this study was to compare the accuracy and reliability of simple methods of
quantifying regional cerebral blood flow (rCBF) with 123l-labeled/V-isopropyl-p …

Brain and whole body distribution ofN-isopropyl-4-iodoamphetamine (I-123) in humans: Comparison of radiopharmaceuticals marketed by different companies in …

H Ito, T Sato, H Odagiri, K Inoue, M Shidahara… - Annals of nuclear …, 2006 - Springer
Abstract Objective Iodine-123 (123 I)-labeled N-isopropyl-4-iodoamphetamine (IMP) has
been used as a cerebral blood flow (CBF) tracer for single-photon emission computed …