Optimized regional myocardial blood flow abnormality detection in dynamic Rb-82 PET
J Tang, A Rahmim, R Lautamaki, MA Lodge… - 2009 - Soc Nuclear Med
467 Objectives The goal is to optimize the dynamic Rb-82 PET reconstruction/acquisition
protocol for maximum detection of reduced regional tracer transport from blood pool to …
protocol for maximum detection of reduced regional tracer transport from blood pool to …
Optimization of dynamic Rb-82 PET cardiac acquisition protocol using Monte-Carlo simulation
J Tang, A Rahmim, R Lautamäki, M Lodge, F Bengel… - 2008 - Soc Nuclear Med
253 Objectives: The goal of this study is to optimize the dynamic Rb-82 PET acquisition
protocol in quantitative studies of tracer transport between blood and myocardial tissue …
protocol in quantitative studies of tracer transport between blood and myocardial tissue …
Test-retest reproducibility of myocardial blood flow from animal dynamic 82Rb PET studies
XB Pan, H Sherif, S Reder, A Preissel, J Declerck… - 2011 - Soc Nuclear Med
1091 Objectives The absolute quantification of myocardial blood flow (MBF) using dynamic
82 Rb PET may provide important clinical information. However, as dynamic imaging and …
82 Rb PET may provide important clinical information. However, as dynamic imaging and …
Cardiac motion-corrected quantitative dynamic Rb-82 PET imaging
J Tang, F Bengel, A Rahmim - 2010 - Soc Nuclear Med
123 Objectives In the context of dynamic cardiac imaging, gating information is not routinely
utilized. Our goal is to introduce gated motion correction within dynamic Rb-82 …
utilized. Our goal is to introduce gated motion correction within dynamic Rb-82 …
Optimization of temporal sampling for 82rubidium PET myocardial blood flow quantification
BC Lee, JB Moody, RL Weinberg, JR Corbett… - Journal of Nuclear …, 2017 - Elsevier
Background Suboptimal temporal sampling of left ventricular (LV) blood pool and tissue time-
activity curves (TACs) may introduce bias and increased variability in estimates of …
activity curves (TACs) may introduce bias and increased variability in estimates of …
Multisoftware reproducibility study of stress and rest myocardial blood flow assessed with 3D dynamic PET/CT and a 1-tissue-compartment model of 82Rb kinetics
Routine quantification of myocardial blood flow (MBF) requires robust and reproducible
processing of dynamic image series. The goal of this study was to evaluate the …
processing of dynamic image series. The goal of this study was to evaluate the …
Quantification of regional myocardial blood flow using dynamic H215O PET and factor analysis
Because the use of factor analysis has been proposed for extracting pure physiologic
temporal or spatial information from dynamic nuclear medicine images, factor analysis …
temporal or spatial information from dynamic nuclear medicine images, factor analysis …
Quantification of myocardial blood flow with 82Rb dynamic PET imaging
M Lortie, RSB Beanlands, K Yoshinaga, R Klein… - European journal of …, 2007 - Springer
Abstract Purpose The PET tracer 82 Rb is commonly used to evaluate regional perfusion
defects for the diagnosis of coronary artery disease. There is limited information on the …
defects for the diagnosis of coronary artery disease. There is limited information on the …
Improved Partial Volume Correction for PET Myocardial Blood Flow Imaging
P1140 Introduction: Partial volume correction (PVC) for PET myocardial blood flow (MBF)
quantification is typically accomplished by the inclusion of a recovery factor (1− vb) in the …
quantification is typically accomplished by the inclusion of a recovery factor (1− vb) in the …
[HTML][HTML] Cardiac PET/CT with Rb-82: optimization of image acquisition and reconstruction parameters
P Chilra, S Gnesin, G Allenbach, M Monteiro, JO Prior… - EJNMMI physics, 2017 - Springer
Background Our aim was to characterize the influence of time-of-flight (TOF) and point
spread function (PSF) recovery corrections, as well as ordered subset expectation …
spread function (PSF) recovery corrections, as well as ordered subset expectation …
Related searches
- rb 82 cardiac pet
- rb 82 reconstruction parameters
- rb 82 image acquisition
- blood flow dynamic pet
- blood flow tissue compartment
- blood flow 82rb kinetics
- blood flow imaging volume correction
- acquisition protocol monte carlo
- tissue compartment dynamic pet
- 82rb kinetics dynamic pet
- blood flow h215o pet
- blood flow pet imaging