Multi-center performance evaluation of a prototype rubidium-82 elution system for low-dose PET myocardial perfusion imaging

J Renaud, A Guo, K Gulenchyn, M Trottier, J Abele… - 2016 - Soc Nuclear Med
1114 Objectives Rubidium-82 (Rb-82) positron emission tomography (PET) myocardial
perfusion imaging (MPI) is gaining more widespread use with its superior diagnostic …

Clinical performance of a prototype rubidium-82 elution system for PET myocardial perfusion imaging

J Renaud, A Guo, L Garrard, R Beanlands, R Dekemp - 2015 - Soc Nuclear Med
442 Objectives Rubidium-82 (Rb-82) PET myocardial perfusion imaging (MPI) has gained
wider use following the Tc-99m shortage with its superior diagnostic accuracy compared to …

Clinical evaluation of a precision-controlled rubidium-82 elution system for PET myocardial perfusion imaging

J Renaud, A Guo, S Rattani, L Garrard, R Beanlands… - 2016 - Soc Nuclear Med
1113 Objectives Positron emission tomography (PET) myocardial perfusion imaging (MPI)
with rubidium-82 (Rb-82) has been more widely adopted due to its superior diagnostic …

New rubidium-82 generator efficiency improves over time

J Renaud, M Wiles, L Garrard, R Beanlands… - 2018 - Soc Nuclear Med
1045 Introduction: PET myocardial perfusion imaging (MPI) with rubidium-82 (Rb-82) is
being more widely adopted due to superior diagnostic accuracy and availability without the …

Rubidium-82 generator yield and efficiency for PET perfusion imaging: Comparison of two clinical systems

A Ahmadi, R Klein, HC Lewin, RSB Beanlands… - Journal of Nuclear …, 2020 - Elsevier
Abstract Introduction Strontium-82/Rubidium-82 (82 Sr/82 Rb) generators are used widely
for positron emission tomography (PET) imaging of myocardial perfusion. In this study, the …

Saline-push improves rubidium-82 PET image quality

JM Renaud, KY Wu, K Gardner, M Aung… - Journal of Nuclear …, 2019 - Elsevier
Abstract Introduction Rubidium-82 (82 Rb) PET is used widely for myocardial perfusion
imaging. The purpose of this study was to investigate if an additional saline-push following …

Minimizing rubidium-82 tracer activity for relative PET myocardial perfusion imaging

ED Huizing, JD van Dijk, JA van Dalen… - Nuclear medicine …, 2017 - journals.lww.com
Objectives Recommended rubidium-82 activities for relative myocardial perfusion imaging
(MPI) using present-generation PET scanners may be unnecessarily high. Our aim was to …

Saline-push improves rubidium-82 PET image quality.

R DeKemp, KY Wu, J Renaud, R Beanlands - 2018 - Soc Nuclear Med
1573 Introduction: Rubidium-82 (82 Rb) PET is used widely for myocardial perfusion
imaging (MPI). The purpose of this study was to investigate if an additional saline-push …

Assessment of a protocol for routine simultaneous myocardial blood flow measurement and standard myocardial perfusion imaging with rubidium-82 on a high count …

D Tout, CM Tonge, S Muthu… - Nuclear medicine …, 2012 - journals.lww.com
Objectives High count rate positron emission tomography (PET) systems offer the potential
for accurate myocardial blood flow (MBF) quantification during first-pass dynamic imaging in …

PET Myocardial Perfusion Imaging: 82Rb

ML De Rimini, G Borrelli - Radiopharmaceuticals: A Guide to PET/CT and …, 2020 - Springer
Abstract Rubidium 82 (82 Rb) is a positron emitter tracer, produced by the nuclear decay of
Strontium-82 by electron capture via a commercially available generator. It is used for PET …