[PDF][PDF] Evaluation of 64Cu-ATSM in vitro and in vivo in a hypoxic tumor model

JS Lewis, DW McCarthy, TJ McCarthy… - Journal of Nuclear …, 1999 - Soc Nuclear Med
MISO in vitro into EMT6 cells was investigated at the dissolved oxygen concentrations of 0, 1
x to3, 5 x 103, 5 x 10" and 2 x 105 ppm. Biodistribution performed at 1, 5, 10, 20 and 40 min …

Cell line-dependent differences in uptake and retention of the hypoxia-selective nuclear imaging agent Cu-ATSM

P Burgman, JA O'Donoghue, JS Lewis… - Nuclear medicine and …, 2005 - Elsevier
BACKGROUND: Cu-diacetyl-bis (N4-methylthiosemicarbazone)[Cu-ATSM] is a potential
marker for tumor hypoxia that has been under evaluation for clinical use. In this study, we …

In vivo assessment of tumor hypoxia in lung cancer with 60Cu-ATSM

F Dehdashti, MA Mintun, JS Lewis, J Bradley… - European journal of …, 2003 - Springer
Tumor hypoxia is recognized as an important determinant of response to therapy. In this
study we investigated the feasibility of clinical imaging with copper-60 diacetyl-bis (N 4 …

Basic characterization of 64Cu-ATSM as a radiotherapy agent

A Obata, S Kasamatsu, JS Lewis, T Furukawa… - Nuclear medicine and …, 2005 - Elsevier
64Cu-diacetyl-bis (N4-methylthiosemicarbazone)(64Cu-ATSM) is a promising radiotherapy
agent for the treatment of hypoxic tumors. In an attempt to elucidate the radiobiological basis …

A comparison of the imaging characteristics and microregional distribution of 4 hypoxia PET tracers

S Carlin, H Zhang, M Reese, NN Ramos… - Journal of Nuclear …, 2014 - Soc Nuclear Med
We compared the imaging characteristics and hypoxia selectivity of 4 hypoxia PET
radiotracers (18F-fluoromisonidazole [18F-FMISO], 18F-flortanidazole [18F-HX4], 18F …

Dosimetry of 60/61/62/64Cu-ATSM: a hypoxia imaging agent for PET

R Laforest, F Dehdashti, JS Lewis… - European journal of …, 2005 - Springer
Purpose Cu-diacetyl-bis (N 4-methylthiosemicarbazone (Cu-ATSM) is an effective marker for
the delineation of hypoxic tissue. Dosimetry calculations by the established Medical Internal …

[HTML][HTML] Hypoxia imaging and theranostic potential of [64Cu][Cu(ATSM)] and ionic Cu(II) salts: a review of current evidence and discussion of the retention …

T Liu, M Karlsen, AM Karlberg, KR Redalen - EJNMMI research, 2020 - Springer
Background Tumor hypoxia (low tissue oxygenation) is an adverse condition of the solid
tumor environment, associated with malignant progression, radiotherapy resistance, and …

Contribution of [64Cu]-ATSM PET in molecular imaging of tumour hypoxia compared to classical [18F]-MISO—a selected review

M Bourgeois, H Rajerison, F Guerard… - Nuclear Medicine …, 2011 - journals.viamedica.pl
During the carcinogenesis process, tumour cells often have a more rapid proliferation
potential than cells that participate in blood capillary formation by neoangiogenesis. As a …

Evaluation of62Cu labeled diacetyl-bis(N 4-methylthiosemicarbazone) as a hypoxic tissue tracer in patients with lung cancer

N Takahashi, Y Fujibayashi, Y Yonekura… - Annals of nuclear …, 2000 - Springer
Abstract 62 Cu labeled diacetyl-bis (N 4-methylthiosemicarbazone)(62 Cu-ATSM) has been
proposed as a generator-produced, positron-emitting tracer for hypoxic tissue imaging. From …

[HTML][HTML] Assessing tumor hypoxia by positron emission tomography with Cu-ATSM

JP Holland, JS Lewis, F Dehdashti - … ,[and] Section of the Society of …, 2009 - ncbi.nlm.nih.gov
For the last several decades, hypoxia has been recognized to be one of the key factors in
tumor aggression and an important impediment to local and distant control of malignant …