Comparison of four commercial Tc-99m (Sn) DTPA preparations used for the measurement of glomerular filtration rate: concise communication.

JE Carlsen, ML Møller, JO Lund… - Journal of Nuclear …, 1980 - europepmc.org
To find a commercially available DTPA preparation that could be used for the measurement
of glomerular filtration rate (GFR), the plasma clearances of four different Tc-99m (Sn) DTPA …

Comparative assessment of techniques for estimation of glomerular filtration rate with 99mTc-DTPA

RM Fawdry, SM Gruenewald, LT Collins… - European journal of …, 1985 - Springer
The relative accuracy of five simplified methods of measuring glomerular filtration rate was
prospectively assessed using 99m Tc-DTPA. The slope of the biological clearance curve …

[PDF][PDF] Quality control of Tc-99m DTPA for measurement of glomerular filtration: concise communication

CD Russell, PG Bischoff, KL Rowell… - Journal of Nuclear …, 1983 - Soc Nuclear Med
When technetium-99m DTPA is used to measure glomerular filtration rate (GFR), the
accuracy dependson the supplierof the radiopharmaceutical. The error in GFR is due to …

Determination of glomerular filtration rate using technetium-99m-DTPA with differing degrees of renal function

KA Morton, DE Pisani, JH Whiting… - Journal of nuclear …, 1997 - Soc Nuclear Med
Glomerular filtration rate (GFR) is an important index of renal function. Twenty-four-hour
creatinine clearance overestimates GFR in patients with poor renal function. Inulin and …

99Tcm–DTPA for the measurement of glomerular filtration rate

AJW Hilson, RD Mistry… - The British Journal of …, 1976 - birpublications.org
Abstract Comparison of the blood clearances of 51Cr–EDTA and 99Tcm–Sn–DTPA, in a
series of 45 patients with a wide range of glomerular filtration rates, showed that there was a …

Accuracy of plasma sample methods for determination of glomerular filtration rate with99mTc-DTPA

K Itoh, S Tsushima, E Tsukamoto, N Tamaki - Annals of nuclear medicine, 2002 - Springer
The plasma sample method following a single injection of radioactive markers has been
proved to be simple and accurate for the determination of glomerular filtration rate (GFR) in …

Measurement of glomerular filtration rate using 99mTc-DTPA and the gamma camera: a comparison of methods

CD Russell, PG Bischoff, F Kontzen, KL Rowell… - European journal of …, 1985 - Springer
A variety of methods have been proposed to estimate the glomerular filtration rate (GFR)
from the renal uptake of technetium Tc 99m-DTPA using a gamma camera. To compare …

[PDF][PDF] Computation of glomerular filtration rate with Tc-99m DTPA: an in-house computer program

GF Gates - Journal of nuclear medicine, 1984 - Soc Nuclear Med
The glomerular filtration rate (GFR) can be computed fol lowing scintigraphic determination
of Tc-99m DTPA (diethy lenetriaminepentaacetic acid) uptake within the kidney (s) at the 2 …

Determination of glomerular filtration rate (GFR) by analysis of capillary blood after single shot injection of 99mTc-DTPA: A comparison with simultaneous 125I …

K Rootwelt, D Falch, R Sjökvist - European Journal of Nuclear Medicine, 1980 - Springer
Abstract 99m Tc-DTPA was prepared from a kit produced by the Institute of Atomic Energy,
Oslo, Norway. Radiochemical purity as determined with gel chromatography ranged from …

Single-sample methods to measure GFR with technetium-99m-DTPA

Y Li, HB Lee, MD Blaufox - The Journal of Nuclear Medicine, 1997 - search.proquest.com
sample calculation of ERPF (r 2 0.905) than both the Schlegel Page 1 scintigraphic technique
and makes it difficult to discern improvements in tERPF estimation. Despite this. the complete …