[PDF][PDF] Autoradiographic comparison of thallium-201 diethyldithiocarbamate, isopropyliodoamphetamine and iodoantipyrine as cerebral blood flow tracers

JL Lear, D Navarro - Journal of nuclear medicine, 1987 - Soc Nuclear Med
Autoradiographic Comparison of Thallium-201 Diethyldithiocarbamate, Isopropyliodoamphetamine
and lodoantipyrine as Cerebral Bloo Page 1 Autoradiographic Comparison of Thallium-201 …

[PDF][PDF] Thallium-201 diethyldithiocarbamate: an alternative to iodine-123 N-isopropyl-p-iodoamphetamine

JF De Bruine, EA Van Royen, A Vyth… - Journal of nuclear …, 1985 - Soc Nuclear Med
The studyof cerebralbloodflow by singlephotonemissioncomputedtomography (SPECT)
requireslipophilicredlopharmaceuticals. The hI@ icost and limftedavailabilityof N-isopropyl p …

[PDF][PDF] Cerebral blood flow imaging with thallium-201 diethyldithiocarbamate SPECT

EA Van Royen, JF De Bruine, TC Hill… - Journal of nuclear …, 1987 - Soc Nuclear Med
MATERIALS AND METHODS Thallium-201 DDC Preparation and Quality Control Fifty
milligrams ofNA-DDC 3 H20'was dissolved in 10ml ofsterile saline. The solution was …

[PDF][PDF] Quantifying local cerebral blood flow by N-isopropyl-p-[123I] iodoamphetamine (IMP) tomography

DE Kuhl, JR Barrio, SC Huang, C Selin… - Journal of Nuclear …, 1982 - Soc Nuclear Med
QuantifyingLocalCerebral BlOOdFlowby N-lsopropyl-p-[1231]lodoamphetamine Page 1
Single-photon emission computed tomography (SPECT) (1,2,23) has been applied to …

Quantitative measurement of regional cerebral blood flow using N-isopropyl-(iodine-123) p-iodoamphetamine and single-photon emission computed tomography.

G Takeshita, H Maeda, K Nakane… - Journal of Nuclear …, 1992 - europepmc.org
We have developed a quantitative method of measuring regional cerebral blood flow (rCBF)
by using N-isopropyl-(iodine-123) p-iodoamphetamine and single-photon emission …

Iodine-122-labeled amphetamine derivative with potential for PET brain blood-flow studies.

CA Mathis, T Sargent 3rd, AT Shulgin - Journal of Nuclear Medicine …, 1985 - europepmc.org
The positron emitter 122I (t1/2 3.6 min) was collected from a xenon-122/iodine-122
(122Xe/122I) generator and incorporated into an amphetamine analog, 2, 4-dimethoxy-N, N …

Comparison of 99Tcm complexes (NEP-DADT, ME-NEP-DADT and HMPAO) with 123IAMP for brain SPECT imaging in dogs

BD Bok, U Scheffel, HW Goldfarb… - Nuclear medicine …, 1987 - journals.lww.com
for brain SPECT imaging in dogs Page 1 Nuclear Medicine Communications 8,631–641(1987)
Comparison of "Tc" complexes (NEP-DADT, ME-NEP-DADT and HMPAO) with *IAMP for brain …

Double-injection method for sequentially measuring cerebral blood flow with N-isopropyl-(123I)p-iodoamphetamine

K Murase, T Inoue, H Fujioka, Y Yamamoto… - Annals of nuclear …, 2000 - Springer
We investigated the accuracy of a double-injection method for sequentially measuring
cerebral blood flow (CBF) with N-isopropyl-(123 I) p-iodoamphetamine (IMP) in simulation …

[CITATION][C] A reawakening of interest in radionuclide brain imaging

RA Holmes - Journal of Nuclear Medicine, 1986 - Soc Nuclear Med
nstitutions performing positron emission tomography (PET) imaging of the brain empha size
the value of the procedure as an investigative tool in studying complex clinical and cognitive …

[PDF][PDF] Early and delayed brain SPECT with technetium-99m-ECD and iodine-123-IMP in subacute strokes

JLM Moretti, F Tamgac, P Weinmann… - Journal of Nuclear …, 1994 - Soc Nuclear Med
R, †Ē. ecentlya neutral lipophilic complex," Tc-ethyl cysteinate dimer (ECD), was
introduced as a tracer for brain perfusion imaging (1, 2) because of its high cerebral reten …