Evaluation of solid-phase labels for gastric emptying studies in cats

JJ Hoskinson, JM Goggin… - The Journal of Nuclear …, 1997 - search.proquest.com
Abstract Development of appropriate radiolabeled diets for solid-phase gastric emptying
studies in experimental animals is important for testing the effects of disease, drugs, surgical …

Evaluation of solid phase radiolabels of dog food for gastric emptying

CP Kunze, JJ Hoskinson, MD Butine… - Veterinary Radiology …, 1999 - Wiley Online Library
99mTc‐Pertechnetate, 99mTc‐mebrofenin, 99mTc‐disofenin, 99mTc‐sulfur colloid, and
99mTc‐Dowex resin beads were evaluated for in vitro stability as a label for both dry …

Comparison of solid food markers in gastric emptying studies

LC Knight, RS Fisher, LS Malmud - Nuclear medicine and biology, 1982 - inis.iaea.org
[en] In studies of gastric emptying of solid foods, it is essential that the radiolabel remain
firmly bound to the food to trace its behavior. Initial studies with radiolabeled solid meals …

Determination of solid-and liquid-phase gastric emptying half times in cats by use of nuclear scintigraphy

M Costello, K Papasouliotis, FJ Barr… - American journal of …, 1999 - Am Vet Med Assoc
Objective To use nuclear scintigraphy to establish a range of gastric emptying half times (t
1/2) following a liquid or solid meal in nonsedated cats. Animals 12 clinically normal 3-year …

Scintigraphic assessment of gastric emptying of canned and dry diets in healthy cats

JΜ Goggin, JJ Hoskinson, MD Butine… - American journal of …, 1998 - Am Vet Med Assoc
Objective To characterize factors that affect solid-phase gastric emptying in healthy cats by
use of nuclear scintigraphy and to assess differences in emptying patterns of dry and …

Gastric emptying of a radionuclide-labeled test meal in healthy dogs: a new mathematical analysis and reference values.

WE Van den Brom, RP Happe - American Journal of Veterinary …, 1986 - europepmc.org
The gastric retention of a semisolid meal, labeled with 99mTc, was measured in 27 clinically
healthy dogs, using a gamma camera coupled to a data acquisition and analysis system. A …

Validation of radioisotopic labelling techniques in gastric emptying studies

R Corinaldesi, V Stanghellini, C Raiti… - Journal of Nuclear …, 1987 - inis.iaea.org
[en] Several techniques are currently employed to label solid and liquid foods with gamma-
emitting radioisotopes in order to carry out gamma-camera gastric emptying studies. The …

Direct comparison of solid-phase gastric emptying times assessed by means of a carbon isotope–labeled sodium acetate breath test and technetium Tc 99m albumin …

S Schmitz, B Götte, C Borsch, C Kunz… - American Journal of …, 2014 - Am Vet Med Assoc
Objective—To directly compare solid-phase gastric emptying times assessed by means of a
[13 C] sodium acetate breath test ([13 C]-SABT) and technetium Tc 99m albumin colloid …

ASSESSMENT OF BARIUM IMPREGNATED POLYETHYLENE SPHERES (BIPS®) AS A MEASURE OF SOLID‐PHASE GASTRIC EMPTYING IN NORMAL DOGS …

NV Lester, GD Roberts, SM Newell… - Veterinary Radiology …, 1999 - Wiley Online Library
Barium impregnated polyethylene spheres (BIPS) are radiopaque markers used for
investigation of a variety of gastrointestinal disorders. One proposed use of the small (1.5 …

The scintigraphic evaluation of solid phase gastric emptying in normal cats

PF Steyn, D Twedt, W Toombs - Veterinary Radiology & …, 1995 - Wiley Online Library
The gastric emptying half‐time of solid food in normal cats was determined using a
scintigraphic technique. 99mTc‐sulfur colloid was applied to dry food. Sequential images …