Technologist Based Implementation of Total Metabolic Tumor Volume into Clinical Practice
J Sullivan, C Olson, M Thorpe, G Johnson, M Jain… - 2021 - Soc Nuclear Med
176 Introduction: Many methods are used to measure metabolic tumor volume (MTV) via
positron emission tomography (PET)(1). These methods may help predict patient outcome …
positron emission tomography (PET)(1). These methods may help predict patient outcome …
Technologist-based implementation of total metabolic tumor volume into clinical practice
E Quinn, C Olson, MK Jain, J Sullivan… - Journal of nuclear …, 2023 - Soc Nuclear Med
Metabolic tumor volume (MTV) is defined as the total metabolically active tumor volume
seen on 18F-FDG PET/CT examinations. Calculating MTV is often time-consuming …
seen on 18F-FDG PET/CT examinations. Calculating MTV is often time-consuming …
Is 18F-FDG Metabolic Tumor Volume in Lymphoma Really Happening?
SF Barrington, AS Cottereau… - Journal of Nuclear …, 2024 - Soc Nuclear Med
Tumor burden influences prognosis in lymphoma, with unidimensional bulk used for risk
assessment and decisions about radiotherapy consolidation (1). Total metabolic tumor …
assessment and decisions about radiotherapy consolidation (1). Total metabolic tumor …
[PDF][PDF] Automated segmentation of TMTV in DLBCL patients: what about method measurement uncertainty?
E Laffon, R Marthan - Journal of Nuclear Medicine, 2020 - Soc Nuclear Med
In baseline 18F-FDG PET imaging of diffuse large B-cell lymphoma (DLBCL) patients,
Barrington et al. recently confirmed that different outlining methods providing total metabolic …
Barrington et al. recently confirmed that different outlining methods providing total metabolic …
A radiomic biomarker characterizing tumor dissemination in patients has complementary predictive value to metabolic tumor volume in a large cohort of diffuse large B …
AS Cottereau, M Meignan, C Nioche, J Clerc… - 2020 - Soc Nuclear Med
270 Objectives: The total metabolic tumor volume (MTV) calculated from baseline 18 F-FDG
PET images is an early prognostic factor in lymphoma. Yet, MTV does not precisely reflect …
PET images is an early prognostic factor in lymphoma. Yet, MTV does not precisely reflect …
In search of platinum meter bar for measurement of metabolic tumor volume in lymphoma
A Gallamini - Journal of Nuclear Medicine, 2019 - Soc Nuclear Med
Barrington and Meignan outline an international project aimed at reaching an expert
consensus on possible standardization of the computation of metabolic tumor volume (MTV) …
consensus on possible standardization of the computation of metabolic tumor volume (MTV) …
Is there an optimal method for measuring baseline metabolic tumor volume in diffuse large B cell lymphoma?
AS Cottereau, I Buvat, S Kanoun, A Versari… - European Journal of …, 2018 - Springer
Dear Sir, Given the absence of a recognized gold standard for assessing the metabolic
tumor volume (MTV) in FDG PET, it is important to discuss the strengths and weaknesses of …
tumor volume (MTV) in FDG PET, it is important to discuss the strengths and weaknesses of …
International benchmark for total metabolic tumor volume assessment in baseline FDG PET/CT of lymphoma patients.
P83 Introduction: Total metabolic tumor volume (TMTV) has been identified as a prognostic
factor in lymphoma patients. However, TMTV cut-off values to identify high versus low-risk …
factor in lymphoma patients. However, TMTV cut-off values to identify high versus low-risk …
Optimal method for measuring baseline metabolic tumor volume in DLBCL patients: are statistical agreements of SUV≥ 2.5 satisfactory?
E Laffon, R Marthan - European Journal of Nuclear Medicine and …, 2018 - Springer
Dear Editor, The prognostic value of the pretreatment total metabolic tumor volume (TMTV)
obtained from quantitative PET measurements in patients with diffuse large B cell lymphoma …
obtained from quantitative PET measurements in patients with diffuse large B cell lymphoma …
Multicenter variability of total metabolic tumor volume estimates in FDG PET.
609 Objectives: Total Metabolic Tumor Volume (TMTV) as assessed by FDG PET is a
valuable biomarker of the disease burden. Yet, TMTV reliability is based on the accuracy of …
valuable biomarker of the disease burden. Yet, TMTV reliability is based on the accuracy of …