A" hybrid" method for measuring myocardial wall thickening from gated PET/SPECT images
I Buvat, ML Bartlett, AN Kitsiou… - The Journal of …, 1997 - search.proquest.com
1989;16:896—901. Page 1 18. James F, Roos M. Minuit. A system for function minimization
and analysis of the parameter errors and correlations Compt. Phys Comma/1 1975;10;343—367 …
and analysis of the parameter errors and correlations Compt. Phys Comma/1 1975;10;343—367 …
Measurement of myocardial wall thickening from PET/SPECT images: comparison of two methods
ML Bartlett, I Buvat, JJ Vaquero, D Mok… - Journal of computer …, 1996 - journals.lww.com
Purpose We compared two methods for measuring myocardial wall thickening from nuclear
medicine perfusion scans. The first method uses the percent change in peak activity, and the …
medicine perfusion scans. The first method uses the percent change in peak activity, and the …
Do patient data ever exceed the partial volume limit in gated SPECT studies?
K Nichols, EG DePuey, MI Friedman… - Journal of Nuclear …, 1998 - Springer
Background Some single photon emission computed tomography (SPECT) methods to
detect percent myocardial wall thickening (% WT) assume a linear relationship to changes in …
detect percent myocardial wall thickening (% WT) assume a linear relationship to changes in …
[PDF][PDF] Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient …
CD Cooke, EV Garcia, SJ Cullom… - Journal of Nuclear …, 1994 - Soc Nuclear Med
The highcountyieldsof@ Fc-sestamit@ make possiblethe acquisitionof multiple gated
SPECT studies with relativelyhigh countdensities. By reonentingthesestudiesinto gatedshort …
SPECT studies with relativelyhigh countdensities. By reonentingthesestudiesinto gatedshort …
Quantification of regional myocardial wall thickening on electrocardiogram-gated SPECT imaging
MYH Shen, YH Liu, AJ Sinusas, R Fetterman… - Journal of Nuclear …, 1999 - Springer
Background Current assessment of regional left ventricular function with electrocardiogram
(ECG)-gated single photon emission computed tomography (SPECT) imaging is generally …
(ECG)-gated single photon emission computed tomography (SPECT) imaging is generally …
[PDF][PDF] Artifactual inhomogeneities in myocardial PET and SPECT scans in normal subjects
ML Bartlett, SL Bacharach… - Journal of Nuclear …, 1995 - Soc Nuclear Med
Results: Two patternsof artifactualinhomogeneitywere found: a depression in activity at the
antero-apex and an elevation in activity in the free wall compared with the septum. Thus, in …
antero-apex and an elevation in activity in the free wall compared with the septum. Thus, in …
Quantitative analysis of regional wall motion and thickening by quantitative gated SPECT: comparison with visual analysis
M Konno, K Morita, I ADACHI, Y Ito… - Clinical nuclear …, 2001 - journals.lww.com
Purpose Electrocardiograph-gated myocardial SPECT permits a quantitative assessment of
global and regional functions by quantitative gated SPECT software. To validate quantitative …
global and regional functions by quantitative gated SPECT software. To validate quantitative …
[PDF][PDF] Quantification of systolic count increase in technetium-99m-MIBI gated myocardial SPECT
K Fukuchi, T Uehara, T Morozumi… - Journal of Nuclear …, 1997 - Soc Nuclear Med
This study was performed to clarify the validity of quantification of myocardial wall thickening
by the count increase method using electrocardiography (ECG)-gated SPECT. Methods: We …
by the count increase method using electrocardiography (ECG)-gated SPECT. Methods: We …
The prolate spheroidal transform for gated SPECT
B Feng, A Sitek, GT Gullberg - IEEE Transactions on Nuclear …, 2001 - ieeexplore.ieee.org
Proposes a method to calculate the volume and surface area of the left ventricle (LV) in the
prolate spheroidal coordinate system. The prolate spheroidal coordinate system is well …
prolate spheroidal coordinate system. The prolate spheroidal coordinate system is well …
Semiautomatic software for quantitative analysis of cardiac positron tomography studies
O Ratib, L Bidaut, C Nienaber, J Krivokapich… - Medical …, 1988 - spiedigitallibrary.org
In order to derive accurate values for true tissue radiotracers concentrations from gated
positron emission tomography (PET) images of the heart, which are critical for quantifying …
positron emission tomography (PET) images of the heart, which are critical for quantifying …